HSC505 - E 8-32 Zone LCD Home Security Controller - Installation Manual
________________________________________________________________________________
Page 7
This document and product are copyrighted and all rights are reserved.
The siren tamper will cause an error to be displayed on all keypads across all partitions, Entering a code
from any partition will clear the error message on all keypads but will not stop the error beep on the keypads
in any other partitions. Press any key to stop the error beep.
Expander board layout:
ZONE 9 .............. Zone 1 input EOL resistor 2K7
C ........................ Common
ZONE 10 ............ Zone 2 input EOL resistor 2K7
ZONE 11 ............ Zone 3 input EOL resistor 2K7
C ....................... Common
ZONE 12 ............ Zone 4 input EOL resistor 2K7
ZONE 13 ............ Zone 5 input EOL resistor 2K7
C ....................... Common
ZONE 14 ............ Zone 6 input EOL resistor 2K7
ZONE 15 ............ Zone 7 input EOL resistor 2K7
C ....................... Common
ZONE 16 ............ Zone 8 input EOL resistor 2K7
Zone wiring - normal:
Normally open detectors are connected in parallel with the end of line resistor.
Normally closed detectors are connected in series with the end of line resistor.
A combination of N/O and N/C may be used.
Zone wiring - dual end-of-line (Tamper)