HSC505 - E 8-32 Zone LCD Home Security Controller - Installation Manual
________________________________________________________________________________
Page 6
This document and product are copyrighted and all rights are reserved.
Motherboard layout:
AC……………….AC input maximum 16.5V 40va
(Earth) ................ This must be connected to building earth were possible, alternately to mains earth
AUX + ................ 12V + to peripherals i.e. IR detectors, beams, etc. (Fused at 1 amp)
Negative to be taken from any negative or common.
TX + ................... Positive to Radio Transmitter (Fused at 3 amps)
TX - .................... Negative to Radio Transmitter
Siren - ................ Negative to Siren (Fused at 3 amps) and supervised See note below
Siren + ............... Positive to Siren
Panic - ................ Panic input EOL resistor 2K7
Panic + .............. Panic input EOL resistor 2K7
Tamper- ............ Tamper Input NO to ground
Tamper+ ........... Tamper Input NO to ground
KEYPAD R + ...... Keypad + (Red)
KEYPAD Y ......... Keypad data (Yellow)
KEYPAD G ........ Keypad data (Green)
KEYPAD B - ....... Keypad (Black)
TRIG O/P 5 ........ Not used
TRIG O/P 4 ........ Trigger Output 4
TRIG O/P 3 ........ Trigger Output 3
TRIG O/P 2 ....... Trigger Output 2
TRIG O/P 1 ....... Trigger Output 1
ZONE 1 .............. Zone 1 input EOL resistor 2K7
C ........................ Common
ZONE 2 .............. Zone 2 input EOL resistor 2K7
ZONE 3 .............. Zone 3 input EOL resistor 2K7
C ....................... Common
ZONE 4 ............. Zone 4 input EOL resistor 2K7
ZONE 5 ............. Zone 5 input EOL resistor 2K7
C ....................... Common
ZONE 6 ............. Zone 6 input EOL resistor 2K7
ZONE 7 ............. Zone 7 input EOL resistor 2K7
C ....................... Common
ZONE 8 ............. Zone 8 input EOL resistor 2K7
Note: The siren output is supervised against an open loop, If no siren is to be used a 2K7 ohm resistor must
be used to strap out the siren.
To monitor the siren for short circuit strap out the siren + and Tamper + with a 2k7 ohm resistor. The Tamper
input must then be programmed as Tamper.