HSC505 - E 8-32 Zone LCD Home Security Controller - Installation Manual
________________________________________________________________________________
Page 17
This document and product are copyrighted and all rights are reserved.
Zone Programming:
Controlled Zones:
Entry/exit - This zone type is the primary entry and final exit point into the premises. Violation of
an entry point when system armed will only start the entry timer. If a valid code is not
entered within the entry time an alarm condition will occur.
Follower - A follower zone becomes an entry exit zone during a valid entry exit procedure. If
the zone is violated outside an entry exit timer, the zone then acts as an instant
zone.
Instant audible - This zone type when activated will cause an instant alarm condition with siren and
communicator activation.
Instant silent - This zone type when activated will cause an instant alarm condition without any
siren activation but with communicator.
Keypad buzzer - This zone type when activated will activate the keypad buzzers only, no siren or
communicator.
24 Hour Zones: (armed or disarmed)
24-hour audible - This zone type when activated will cause an instant alarm condition with siren
and communicator.
24-hour silent - This zone type when activated will cause an instant alarm condition without any
siren but with communicator.
24-hour fire - This zone type when activated will cause an instant alarm condition with siren
and communicator. The siren output to differentiate a fire condition will be pulsed.
Keypad buzzer - This zone type when activated will activate the keypad buzzers only, no
siren or communicator.
Keyswitch - This zone when activated will cause the system to change its armed / disarmed
state.
NOTE: only zones 16; input 1(zone 33); input 2 (zone 34); input 3 (zone35) may be
selected as keyswitch zones to work across partitions 1 to 4.