EasyManua.ls Logo

QSC PowerLight 6.0 II - Appendix; Dataport Pinout

QSC PowerLight 6.0 II
28 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
25
APPENDIX-
DataPort Pinout
The DataPort connection is QSC-specific. Informa-
tion is subject to change.
SPECIFICATIONS- PowerLight 6.0 II Electrical Data
QSControl Control and Monitor Parameters on/standby, channel gain, mute, polarity, input level, output level, heat sink
temperature, output load sense, clip detect, protect detect, operating Mode
sense (Stereo/Parallel/Bridge)
Cooling four continuously variable speed fans, rear to front airflow
Amplifier Protection short circuit, open circuit, thermal, ultrasonic, and RF protection
stable into reactive or mismatched loads
Load Protection turn-on and turn-off muting, DC fault power supply shut down
Weight 53 lbs (net), 60 lbs (shipping)
Power Requirements 120 Volts AC, 50 to 60 Hertz, 30 Amp NEMA L5-30 receptacle
OR
240 Volts AC, 50 to 60 Hertz, 15 Amp service
Current Consumption
(in amperes, rms)
Current Consumption Notes: Typical- 1/8 power, pink noise, represents typical program with occasional clipping
Full- 1/3 power, pink noise, represents severe program with heavy clipping
Maximum- continuous sine wave at 1% clipping
Note: Specifications are subject to change without notice.
Pin Signal Description
1 Ch. 1 Minus (-) Input Signal
2 AC Standby Control
3 V- MON Ch. 1 and Subcode 1
4 I- MON Ch. 1 and Subcode 2
5 Clip/Protect Ch. 1
6 Hard Ground
7 Ch. 1 Plus (+) Input Signal
8 Ch. 2 Plus (+) Input Signal
9 +15V from Amplifier
10 Data Reference Ground
11 Ch. 2 Minus (-) Input Signal
12 Amplifier IDR (Model ID)
13 V- MON Ch. 2 and Subcode 3
14 I- MON Ch. 2 and Subcode 4
15 Clip/Protect Ch. 2
120 Volts