NOTE: Power consumption needs to increase or decrease by at least 1 Watt to be reported,
REGARDLESS of the percentage set in this parameter.
Parameter no. 42 Power reporting in Watts by time interval for Q1 or Q2
The set value refers to the time interval with which the power consumption in Watts is reported
(0 32767 seconds). If 0 is entered, energy consumption reports will not be sent to the gateway
(hub).
Values (size is 2-byte dec):
default value 0
0 - Power consumption reporting disabled
1 32767 = 1 - 32767 seconds. Power consumption reporting enabled. Report is sent
according to time interval (value) set here.