Parameter no. 73 Slats position
This parameter is used to enable/disable the slats to return to the previously set position after
being activated via the Z-Wave gateway(hub), push-button operation or when the lower limit
switch is reached.
Values (size is 1-byte dec):
default value 1
0 - disable
1 - enable
Parameter no. 74 Motor moving up/down time
This parameter defines the time, required by the Shutter motor, to completely open or
completely close the attached shutters.
Values (size is 2-byte dec):
default value 0
0 moving time disabled (working with limit switches)
1 - 32767 = 0.1seconds 3276.7 seconds
After the set time passes, the motor stops (relay goes to the off state).
NOTE: It is important that the reference position, for setting the moving time, is always when the
Shutter is at its lowest position!
Set parameter 74 to 0 and move the Shutter (using the up/down push-buttons or the main
gateway (hub) UI) to the lowest desired position. When the Shutter reaches this position, set the
parameter 74 to the duration, required by the Shutter, to completely open or completely close