TECHNICAL DATA
GB
QUICK
®
RESERVES THE RIGHT TO MODIFY THE TECHNICAL CHARACTERISTICS OF THE EQUIPMENT AND THE CONTENTS OF THIS MANUAL WITHOUT PRIOR NOTICE.
MODEL
SBC100 ADV PLUS SBC140 ADV PLUS SBC250 ADV PLUS SBC285 ADV PLUS
SBC100 ADV DR PLUS SBC140 ADV DR PLUS SBC250 ADV DR PLUS SBC285 ADV DR PLUS
260÷207 Vac (260÷207 Vac or 130÷103 Vac
(5) (*)
)
45÷66 Hz
1,2 A 1,8 A 3,2 A 3,2 A
2,4 A 3,6 A 6,4 A 5,6 A
INPUT CHARACHTERISTICS
OUTPUT CHARACTERISTICS
Maximum output current
(1)
Charge absorption voltage
Charge float voltage
Residual ripple
(2)
Charging characteristics
Number of outputs
(3)
8 A 12 A 25 A 12 A
14,1 Vdc (14,4 Vdc GEL) 28,2 Vdc (28,8 Vdc GEL)
13,5 Vdc (13,8 Vdc GEL) 27,0 Vdc (27,6 Vdc GEL)
30mV RMS maks
Automatic in three stages IU
o
U
2 3 2
Supply voltage
(4)
Frequency
Maximum absorption (230 Vac)
(6)
Maximum absorption (115 Vac)
(6) (*)
Aluminium - Cycoloy ®
Anodized - OR5066
155 x 205 x 75 mm 155 x 268 x 75 mm
1,1 Kg 1,2 Kg 2,0 Kg
CASE
Material
Colour
Dimensions (WxHxD)
Weight
Yes, through fuse
Yes
Yes
Yes
PROTECTION
Reverse polarity
(7)
Overload
Output short circuit
Overheating
-20 to +70 °C, with power reduction over +50 °C
Natural Forced, with controlled fan
Max. 95% RV without condensation
AMBIENT CHARACTERISITCS
Operating temperature
Cooling
Humidity
No Yes No
EN 60335-2-29
EN 55022/B
GENERAL
Connector for remote panel
Safety classification
EMC class
(*)
Only DR models
(1)
Maximum value at normal use or in short circuit.
(2)
At maximum output current on resistive load.
(3)
Each output can supply the maximum value of nominal current. The sum of the currents supplied from each output can not exceed
the maximum nominal value of the equipment.
(4)
Without power derating.
(5
)
The battery charger measure the input AC voltage and choose the correct working input range.
(6)
With supply voltage specified as and output current equal to the maximum nominal value.
(7)
The protection could be inefficient in some operative conditions.
Cycoloy
®
is a registered trade mark of GE Plastics.
TECHNICAL DATA