16
Quicksilver 605OP — System & Component Overview and Operaon
If water does not come out of the discharge hose:
1. Remove the motor module to see if the impeller rotates with the power on.
2. Remove any debris that may have accumulated in the nozzle secon or strainer base.
3. Check hose and connecon on hull side for debris and proper connecons.
4. If water ever entered the forward part of the bilge, the water can sll be evacuated by the
bilge pump.
If water ever enters the forward part of the bilge, there is an inspecon plate located in the console,
when removed, allows access to a drain plug. Simply remove the drain plug in the PVC pipe to allow
the water to drain a. Once all of the water has drained, re-install the drain plug.
Inspecon plate
Drain plug
Forward Drain Plug
Check the funcon of all bilge pumps at regular intervals.
Clear pump inlet from debris.
The bilge pumping system is not designed for damage
control.
Do not operate vessel unless the forward drain plug is
properly installed and secured. If the plug is not installed
and secured in place, fuel vapors and / or Carbon Monoxide
can migrate forward into areas that do not have proper
venlaon. This could lead to serious injury or death.
4. Fire Prevenon
Fire is a serious boang hazard. Boats will burn quickly. Do not remain onboard and ght a re for
more than a few moments. If the re is out of control and cannot be put out with the re suppression
equipment onboard, abandon ship immediately.
The boat, when in service shall be equipped with the following portable re exnguishers:
1. Fire Rang 13A 89B C
The boat owner/operator shall:
1. Have the re ghng equipment checked at the intervals indicated on the equipment.
2. Replace portable re exnguisher, if expired or discharged, by devices of idencal re ghng
capacity.