28
! WARNING
Do not mix different grades or types of fluid. Do not use inferior grades of fluids.
Failure to follow these recommendations could cause serious fluid breakdown,
resulting in the information of heavy varnish and sludge throughout the system.
This could result in clogging the fluid separators, coolers and internal fluid
passages. Warranty will be voided.
7. Fluid Filter
The fluid filter is a spin on, full flow unit. Replacement of the filter requires spinning off the complete cartridge and
replacing it with a new one.
USE GENUINE QUINCY REPLACEMENT FILTERS ONLY.
The initial filter change should occur after the first 500 hours of operation. During normal service, the filter
cartridge should be replaced under the following conditions,
whichever occurs first
:
As indicated by the fluid filter maintenance indicator when the fluid is up to its operating temperature.
Every 1,000 hours.
Every fluid change.
NOTE:
The fluid filter maintenance indicator may read high upon start up on cool mornings due to sluggish fluid
creating higher than normal differential pressures. Monitor indicator after the fluid warms up. Do not
confuse the fluid filter with the strainer located before the fluid pump.