CAUTIONS:
TURN OFF ALL POWER AT CIRCUIT BREAKER/FUSE PANEL.
• Read entire Installation Manual before proceeding.
• All wiring should comply with local electrical codes and
requires a qualied electrician
• The total lighting load connected to a STEALTH must not exceed 8
amps (1000 watts incandescent). To switch more wattage an electrician
can install a relay.
• Line Carrier Remote Control Systems such as X-10, Levitron or Radio
Shack are incompatible with sensors and cause false activations.
• Do not install sensors on a circuit that feeds motor loads like kitchen
appliances, HVAC equiptment, washer/dryer, or garagedoor openers.
• Sensor must be below and as far as possible away from lights.
• Sensor functions best when the direction of expected
movement is across its detection pattern, not towards the sensor.
• Mount 6-12 feet high for optimum range and detection.
Mounting Plate:
STL200 Floodlight kits come with the RAB CU4 EZ plate, allowing for
mounting on round, rectangular or octogonal surface or recessed box.
Mounting