10W LED WALLPACK INSTALLATION INSTRUCTIONS
IMPORTANT
READ CAREFULLY BEFORE INSTALLING FIXTURE. RETAIN THESE INSTRUCTIONS FOR FUTURE REFERENCE.
RAB xtures must be wired in accordance with the National Electrical Code and all applicable local codes. Proper
grounding is required for safety. THIS PRODUCT MUST BE INSTALLED IN ACCORDANCE WITH THE APPLICABLE
INSTALLATION CODE BY A PERSON FAMILIAR WITH THE CONSTRUCTION AND OPERATION OF THE PRODUCT.
WARNING: Make certain power is OFF before installing or maintaining xture. No user serviceable
parts inside.
Thank you for buying RAB lighting
xtures. Our goal is to design the
best quality products to get the job
done right. Wed like to hear your
comments. Call the Marketing
Department at 888-RAB-1000, or
email: marketing@rabweb.com
JUNCTION bOx MOUNT fOR
CONDUIT
For use on retrot applications that make conduit
necessary.
Loosen and remove (3) Lens Screws. Remove
Door.
Loosen and remove (2) Housing Screws. Remove
Housing from Back Box. Keep Gasket intact for
re-assembly.
Secure Back Box to the mounting surface using
hardware appropriate for that mounting surface.
Wire the xture using UL approved wire connectors
and according to NEC and local codes. Apply
sealant to all unused conduit entry points.
Place Gasket between Back Box and Housing.
Re-mount Housing to Back Box. Check Gasket
seal all around the Back Box.
Re-mount Door to Housing. Tighten (3) Lens
Screws. Check Door gasket seal.
Fixture can be mounted upside down in dry and
damp locations only.
1.
2.
3.
4.
5.
6.
7.
Lens
Screws
SURfACE MOUNT fOR
RECESSED bOx
For use with recessed junction box and wiring.
Use supplied crossbar. Mount Crossbar to recessed
junction box with (2) screws.
Place Gasket on back of the xture. Gasket should
create seal against mounting surface.
Wire xture to supply wires in recessed box according
to wiring section.
Use 1/4 x 20 stainless steel Mounting Screw to
attach xture to Crossbar. Tighten Mounting Screw.
Cover screw with Cap, provided.
Fixture can be mounted upside down in dry and damp
locations only.
1.
2.
3.
4.
5.
6.
WPLED10
Junction Box
WPLED10S
Surface Mount
Crossbar
Gasket
Mounting
Screw
Cap
Back Box
Gasket
Housing
Door
Housing
Screws
Recessed
Junction
Box