MAINTENANCE INSTRUCTIONS
37
P
ARAMETER
P07
-
M
INIMUM CENTRAL HEATING OUTPUT
12. Enter the parameters menu and select parameter P07.
The pressure gauge will indicate the gas pressure. If this
pressure value is different to that on the rating plate of the
boiler (see paragraph 5.4 ‘Gas Data’), use and
buttons (D.H.W temperature setting) to modify the value
of the parameter. The range of settings is 00 - 80.
13.
Press mode selection button to confirm and to
render the new adjustment operative. The parameter
number (P07) will appear on the display.
14.
Press simultaneously and buttons until
OFF
appears on the display.
15. Disconnect the pressure gauge from the pressure tale-off
point ‘B on the gas valve and carefully tight the screw making
sure there are no gas leaks.