MAINTENANCE INSTRUCTIONS
38
P
ARAMETER
P09
S
ETS THE IGNITION SEQUENCE
This parameter is used to set the gas pressure during the starting up of
the boiler..
To enter the parameters menu, follow the previously described
procedure (see paragraph 5.2 ‘Accessing the parameters menu’ -
steps 1-5).
6. Use and buttons (D.H.W temperature setting) to
modify the value of the parameter within the prescribed limits:
00 = minimum mechanical
gas pressure set at the gas valve;
99 = maximum allowed pressure, depending on the chimney length
and the type of gas used.
The default value is 50.
7.
Press mode selection button to confirm and to render the
new adjustment operative. The parameter number (P09) will appear
on the display.
8.
To exit from the parameters menu, press simultaneously and
’ buttons.
P
ARAMETER
P10
D.H.W.
P
RIORITY FUNCTION
(Not applicable to instantaneous boilers w/dual circuit exchanger)
This parameter allows to maintain the diverter valve on D.H.W mode
for a time equal to the post-circulation, keeping hot the secondary heat
exchanger.
To enter the parameters menu, follow the previously described
procedure (see paragraph 5.2 ‘Accessing the parameters menu’ -
steps 1-5).
6. Use and buttons (D.H.W temperature setting) to
modify the value of the parameter:
00 = Off
01 = On
7.
Press mode selection button to confirm and to render the
new adjustment operative. The parameter number (P10) will appear
on the display.
8. To exit from the parameters menu, press simultaneously and
’ buttons.
P
ARAMETER
11
LEGIONELLA PREVENTION FUNCTION
(For storage boilers only)
To enter the parameters menu, follow the previously described
procedure (see paragraph 5.2 ‘Accessing the parameters menu’ -
steps 1-5).
6. Use and buttons (D.H.W temperature setting) to
modify the value of the parameter:
00 = Off
01= On (default value in storage boilers)
7.
Press mode selection button to confirm and to render the
new adjustment operative. The parameter number (P11) will appear
on the display.
8. To exit from the parameters menu, press simultaneously
and
’ buttons.
50
P09
00
P10
01
P11