MAINTENANCE INSTRUCTIONS
41
P
ARAMETER
P15
D.
H
.
W
.
MAXIMUM SET POINT
This parameter is used to set the D.H.W maximum user set
point.
To enter the parameters menu, follow the previously described
procedure (
see paragraph
5.2 ‘Accessing the parameters
menu’
- steps 1-5).
6.
Use and buttons (D.H.W temperature setting)
to modify the value of the parameter within the prescribed
limits (displayed in Celsius degrees):
45 – 75
45–60 (for instantaneous boiler (w/dual circuit exchanger)
7.
Press mode selection button to confirm and to render
the new adjustment operative. The parameter number (P15)
will appear on the display.
8.
To exit from the parameters menu, press simultaneously
and ‘ ’ buttons.
P
ARAMETER
P16
P
OST VENTILATION
This parameter is used to set the fan functioning time, after
switching off the burner.
To enter the parameters menu, follow the previously described
procedure (
see paragraph
5.2 ‘Accessing the parameters
menu’
- steps 1-5.
6.
Use and buttons (D.H.W temperature setting)
to modify the value of the parameter within the prescribed
limits (displayed in minutes):
00 - 10
7.
Press mode selection button to confirm and to render
the new adjustment operative. The parameter number (P16)
will appear on the display.
8.
To exit from the parameters menu, press simultaneously
and ‘ ’ buttons.
60
P15
00
P16