EasyManua.ls Logo

Radiant Slim RBA CS 100 E - Technical Data

Radiant Slim RBA CS 100 E
38 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Installation Manual
Floor standing storage boiler – Cod. 99949NA – November 2002
2
TECHNICAL DATA
Type C unit
Type C devices are devices in which the combustion circuit (air
intake, combustion chamber, exchanger, combustion exhaust) is
sealed off from the place where they are installed.
CENTRAL HEATING - DOMESTIC HOT WATER
sealed combustion circuit type
RBA CS 24 E - electronic ignition
RBA CS 100 E - electronic ignition
Technical data
MODEL RBA CS 24 E RBA CS 100 E
Maximum rated input
KCal/h
25628 25628
Kw
29.80 29.80
BTU/h
101692 101692
Minimum rated input
KCal/h
15000 15000
Kw
17.5 17.5
BTU/h
59250 59250
Maximum rated output
KCal/h
23090 23090
Kw
26.85 26.85
BTU/h
91621 91621
Minimum rated output
KCal/h
12900 12900
Kw
15 15
BTU/h
12900 12900
Heting temperature adjustment
°C
30-80 30-80
Max. working pressure (heating)
bar
3 3
Min. working pressure (heating)
bar
0.3 0.3
Expansion vessel capacity (initial pressure 1 bar)
Litres
10 8
Hot stored water max. temperature
°C
60 60
Continuous hot water drawing with t 30°
Litres/h
807 858
Maximum continuous mixed drawing with t 30°, first 10 minutes
Litres
175 255
Max. working pressure (water)
bar
6 6
Min. working pressure (water)
bar
0.3 0.3
Width
mm.
600 570
Height
mm.
850 1640
Depth
mm.
600 570
Weight
Kg.
78 116
Flue diameter
Ø
100/60
80/80
100/60
80/80
Flow/return connections
3/4”- 3/4” 3/4”- 3/4”
Cold water connections
Ø
1/2” 1/2”
Hot water connections
Ø
1/2” 1/2”
Gas connections
Ø
1/2” 1/2”
Electrical connection 50 Hz
V
230 230
Power supply
W
170 170
Burner jets NP 24 G20
Ø
1.25 1.25
Gas category:
IT II2H3 Gas supply pressure: G20 20 mbar / G30/31 29-30/37 mbar
FORCED CIRCULATION
Coaxial vertical
Coaxial horizontal
C32
C12
C52 Double

Related product manuals