Default RADWIN 2000 Settings Chapter 4
RADWIN 2000 User Manual Release 2.6.40 4-10
Installation actually gets the link operational by setting the link parameters. It uses a fixed
channel at the lowest possible modulation, BPSK at 6.5Mbps and will work under the harsh
interference condition.
2. Link Configuration - described in Chapter 7.
Configuration provides much the same functionality as Installation, but for a running link.
A fallback to Installation mode is provided for situations which cannot be handled without
resetting the link, such as antenna realignment and IDU or ODU replacement.
The Link Installation and Configuration phases are both carried out with Wizards, which
“walk you through” the processes. The Wizards are visually quite similar and will be
described in detail below.
3. Site Configuration - described in Chapter 8.
Site specific configuration for each side of the link is available at any time - under a run-
ning link or under the restricted Installation mode.
Site Configuration consists of a set of panels, which may be invoked individually in any
order, as needed.
Default RADWIN 2000 Settings
The default settings of the RADWIN 2000 configuration parameters are listed in the second
column of Table 4-3 below. The third column shows the values we use in this manual for
illustrative purposes.
Note
During the installation procedure, the definition of all parameters is
automatically applied to both sides of the link.
Caution
The ODUs as supplied by RADWIN are set up with a factory default
band. If for some reason the default band needs to be changed, it
should be done before link Installation. The procedure is set out in
Chapter 20.
Use of an incorrect band may be in violation of local regulations.
Note
An installed and configured link can be returned to installation mode for re-
installation and configuration from last settings or from factory settings.
Reversion to installation mode requires a complete break in the link
service
Configuration mode may vary the service throughput and quality, but
without a service break
Table 4-3: Default Settings
Parameter Default Value Illustrative Value
Factory default band Product dependent 5.820GHz
ODU IP Address 10.0.0.120 192.168.1.101 and 102
Subnet Mask 255.0.0.0 255.255.255.0