VIII.
CLEANING HARNESS CONNECTOR
1.
If harness connector is not connecting or is leaking,
disconnect from tubing and clean thoroughly with a
mixture of isopropyl alcohol and water.
If problem persists, soak overnight in 70%
isopropyl alcohol.
2.
If the connector stops functioning in the
field, remove the harness connector and
connect both sides of the harness to a
black push-to-connect tee that will feed
directly from the bottle to finish the work.
Clean or replace the harness connector.
3.
IX.
BOTTLE CAP MAINTENANCE
Add silicone lubricant to
the X-ring.
1.
Inspect dip tube for obstructions.
2. 3.
Clean away any residue or
debris from components.
If a component
must be removed
or replaced, it is
recommended
to re-seal the
threads with
pipe sealant or a
medium strength
thread lock
product.
4.
13
Lubricant
1 part
70% isopropyl
alcohol
+
2 parts
water
Cleaning
Solution
TABLE OF CONTENTS
Q-CONNECT OVERVIEW
INSTRUCTIONS FOR USE
PHASE 1 - GETTING SET UP
PHASE 2 - DRILLING INJECTION SITES
PHASE 3 - INJECTING
PHASE 4 - CLEANING
GENERAL CARE & STORAGE
APPROVED PRODUCTS LIST
TROUBLESHOOTING
MAINTENANCE
REPAIR INSTRUCTIONS
1
2-5
2
3
3-4
4-5
6
6
7-8
8-9
10-13
For tech support and protocols call 877-272-6747