Safety Statements

Basic Requirements

Read this document carefully before installing and using the ISCOM HT803G-1GE.

Environmental Requirements

Place the device in an environment with good ventilation and no direct exposure to strong light.

Electric Safety

Use the original power adapter included in the package or replacement provided by Raisecom.

Laser Safety

Personnel operating the fiber must be trained on laser safety.

Other Precautions

If any abnormality occurs, stop using the device immediately and contact support.

Device Specifications

Technical Specifications

Table 3-1 lists technical specifications of the ISCOM HT803G-1GE.

Packing List

Table 3-3 lists packing list of the ISCOM HT803G-1GE.

LED Indicators

LED Status Overview

Provides a comprehensive overview of all device LED indicators and their meanings.

Interfaces and Buttons

Installation Modes

Connecting Power Supply

Powering On Device

Accessing Device

Frequently Asked Questions (FAQ)

LED Status Troubleshooting

Addresses common issues and troubleshooting steps for Power, PON, LOS, and LAN LEDs.

RoHS Compliance Declarations

Overview

The ISCOM HT803G-1GE (T) is an integrated device designed for network connectivity, specifically functioning as a Passive Optical Network (PON) terminal. It provides a reliable and efficient solution for delivering high-speed data services. The device is built with precision components, emphasizing the need for careful handling to prevent damage.

Function Description:

The primary function of the ISCOM HT803G-1GE (T) is to serve as an Optical Network Unit (ONU) or Optical Network Terminal (ONT) in a Gigabit Passive Optical Network (GPON) system. It connects to the Optical Line Terminal (OLT) at the service provider's end via a single optical fiber, enabling the transmission and reception of data. The device features a PON interface for optical fiber connection and an Ethernet interface for local network connectivity, allowing users to connect their computers or other network devices. It supports high-speed data transfer, making it suitable for various broadband applications. The device is designed to be powered by an external power adapter, ensuring stable operation.

Usage Features:

The ISCOM HT803G-1GE (T) is designed for straightforward installation and operation. It can be installed on a stable workbench or, as recommended for better stability and to prevent damage, mounted on a wall. Wall-mount installation involves knocking two cement nails into the wall, aligning the device's wall-mount holes with the nails, and hanging the device securely. The device's compact dimensions and light weight contribute to its ease of placement.

Connecting the device involves a few simple steps:

  1. Power Supply Connection: The device uses an external power adapter with an input of 100–240 VAC (50/60 Hz) and an output of 12 VDC, 0.5 A. Users must insert the 12 VDC power adapter plug into the device's power interface and the 100–240 VAC plug into an AC power socket. It is crucial to use the original power adapter or a Raisecom-provided replacement to avoid device damage.
  2. Powering On: After connecting the power supply, the device is powered on by pressing the POWER button. A green Power LED indicates that the device is powered on correctly. Following a Power-On Self-Test (POST) and initialization, the device enters its working status.
  3. Network Access: To access the device, users need to connect it to a PC via an Ethernet cable. The PC's IP address should be configured within the same subnet as the device (e.g., 192.168.1.X, where X is between 2 and 254, with a subnet mask of 255.255.255.0). Users can then open a web browser, type "http://192.168.1.1" into the address bar, and press Enter to access the Web login interface. The default username is "telecomadmin" and the password is "q!w@e#".

The device features several LED indicators to provide status information:

  • Power LED (Green): Indicates normal power supply (green) or power off/abnormal (off).
  • PON Registration LED (Green): Shows registration status (green for complete, blinking green for ongoing, off for incomplete).
  • Ethernet Interface Status LED (Green): Indicates proper Ethernet interface operation (green) or data transmission (blinking green).
  • Optical Power LED (Red): Blinks red if the Rx optical power of the PON interface is smaller than Rx sensitivity, and is off if the Rx optical power is normal.

The device also includes a Reset button. Pressing it for 2-5 seconds restarts the device, while pressing it for over 5 seconds restores factory settings.

Maintenance Features:

Maintaining the ISCOM HT803G-1GE (T) involves adhering to safety guidelines and performing basic troubleshooting.

Environmental Requirements:

  • The device should be placed in a well-ventilated environment, away from direct strong light.
  • It must be kept clean and free from dust, water, and moist areas.
  • No objects should be placed on the device to prevent overheating or deformation.
  • The device should be kept away from heat or fire sources (e.g., electric heaters, candles) and strong magnetic or electric fields (e.g., microwave ovens, refrigerators).

Electric Safety:

  • Only the original or Raisecom-provided power adapter should be used.
  • The power supply voltage and current must meet the specified requirements, and overcurrent protection is necessary.
  • The power plug should be kept clean and dry to prevent electric shock.
  • Before disconnecting any cables, the device should be powered off.
  • If the device is not used for an extended period, it should be powered off and unplugged.
  • In case of liquid ingress, the device must be immediately powered off, all cables disconnected, and Raisecom technical support contacted.

Laser Safety:

  • Personnel operating the fiber must be trained in laser safety.
  • Fibers should not be bent excessively (diameter smaller than 7.5 cm or 3 inches) to avoid damage or signal blockage.
  • Users must avoid staring into the optical interface or fiber end face to prevent eye injury.

Other Precautions:

  • In case of abnormalities like smoking, abnormal sounds, or peculiar smells, the device should be immediately powered off, all cables disconnected, and Raisecom technical support contacted.
  • No objects (especially metal) should be allowed to enter the device through heat dissipation holes.
  • The device shell should not be scraped or abraded to prevent malfunction or human allergy.
  • Children should not be allowed to play with the device or its components to avoid hazards.

Troubleshooting (FAQ):

The manual provides guidance for common issues:

  • Power LED off: Check if the POWER button is pressed, if the correct power adapter is used, and if connections are firm. Verify the adapter's output voltage (12 V).
  • PON LED off: Check if the fiber is working properly, connected correctly, and clean. Verify optical attenuation and LOID matching with the OLT.
  • LOS LED blinking: Check if the fiber connector is properly inserted and clean.
  • LAN LED off: Check if the Ethernet cable meets standards and is properly connected. Verify if the Network Interface Card (NIC) LED is lit. If the NIC is not working, check its status in Device Manager, reinstall drivers, or try another slot/NIC.

By following these guidelines, users can ensure the safe and effective operation and maintenance of their ISCOM HT803G-1GE (T) device.

Raisecom ISCOM HT803G-1GE T Specifications

General IconGeneral
Device TypeGateway
ModelISCOM HT803G-1GE T
Operating Temperature0°C to 40°C
Storage Temperature-40°C to 70°C
WANGPON
Power Supply12V DC
Weight200g
Ports1 GE