3
Item
Description
Package check
Before installing the device, check whether the device model and auxiliary parts in the package
box comply with the Packing List. If not, contact Raisecom local office or dial our hotline for
technical support.
Installation scenario
Cabinet: ETSI 600-mm cabinet, 19-inch 450-mm cabinet, or 19-inch 600-mm cabinet
Open rack
Operating
temperature
045°C
Operating humidity
10%90% RH (non-condensing)
Air pressure
86106 kPa
Anti-seismic grade
8
Power supply
conditions
The power consumption is 44 W when the device is at standard load and 65 W when the device
is at maximum load. Therefore, the power supplied by the power supply must be greater than the
maximum power consumption.
DC power
-48 VDC, -38 to -72 VDC
Receptacle connector
AC power
110/220 VAC, 100240 VAC, 50/60 Hz
3-pin phoenix connector
ESD protection
Use effective ESD measures. The contact discharge voltage is ±8 kV, and the air discharge
voltage is ±15 kV.
Grounding condition
The device should adopt common earthing mode, with a ground resistance not greater than 1 Ω.
Installation tools
Flathead screwdriver, Philips screwdriver, adjustable spanner, cable cutter, wire stripper, ESD
glove, ESD wrist strap, PON optical power meter, multimeter, ground resistance tester, cable
tester, and crystal head crimping pliers
Dimensions: 440 mm (Width) × 266 mm (Depth) × 44 mm (Height).
The following table describes componets of the ISCOM5508-GP.
Type
Name
Description
MCC
GPSC
Control, management, aggregation, and
switching card
Expansion subcard
GP4A
4 GPON subcards

Other manuals for Raisecom ISCOM6820-GP