Remote Commands
R&S
®
FSVA3000/ R&S
®
FSV3000
971User Manual 1178.8520.02 ─ 01
Suffix:
<n>
.
Window
Manual operation: See " Set to Default " on page 512
DISPlay[:WINDow<n>]:SGRam:COLor:LOWer <Percentage>
DISPlay[:WINDow<n>]:SPECtrogram:COLor:LOWer <Percentage>
This command defines the starting point of the color map.
Suffix:
<n>
.
Window
Parameters:
<Percentage> Statistical frequency percentage.
Range: 0 to 66
*RST: 0
Default unit: %
Example:
DISP:WIND:SGR:COL:LOW 10
Sets the start of the color map to 10%.
Manual operation: See " Start / Stop " on page 511
DISPlay[:WINDow<n>]:SGRam:COLor:SHAPe <Shape>
DISPlay[:WINDow<n>]:SPECtrogram:COLor:SHAPe <Shape>
This command defines the shape and focus of the color curve for the spectrogram
result display.
Suffix:
<n>
.
Window
Parameters:
<Shape> Shape of the color curve.
Range: -1 to 1
*RST: 0
Manual operation: See " Shape " on page 511
DISPlay[:WINDow<n>]:SGRam:COLor:UPPer <Percentage>
DISPlay[:WINDow<n>]:SPECtrogram:COLor:UPPer <Percentage>
This command defines the end point of the color map.
Suffix:
<n>
.
Window
Parameters:
<Percentage> Statistical frequency percentage.
Range: 0 to 66
*RST: 0
Default unit: %
Analyzing Measurements (Basics)