- 73 -
Fault
message
When and how Remedial action
Service 24 Displayed continuously. Switch the unit off and notify Customer Service.
Service 25 Displayed for 30 seconds during
CleanJet
®
+care cleaning.
CleanJet
®
+care is not working.
- Open the water tap fully
- Check the incoming screen
- Remove the container from the cooking cabinet
- If no faults are found, please notify Customer
Service.
- If Service 25 occurs during CleanJet
®
+care cleaning,
please remove the tabs from the cooking cabinet
and rinse the cooking cabinet thoroughly with the
hand shower (also behind the air baffle)
- The unit can be used for cooking temporarily.
Please notify Customer Service.
Service 26 Displayed continuously. If the fault message occurs during CleanJet
®
+care
cleaning, please run "Interrupt CleanJet
®
”. If the
fault message continues to be displayed after run-
ning "Interrupt CleanJet
®
", remove the tabs from
the cooking cabinet and rinse the cooking cabinet
thoroughly with the hand shower (also behind the air
baffle). Please notify Customer Service.
Service 27 When it has been switched on for
30 seconds,
CleanJet
®
+care is not possible. Switch off the power
at the mains for 5 seconds, then switch on again.
Service 28 When it has been switched on for
30 seconds,
Please notify Customer Service.
Service 29 Displayed continuously. Check the air filter under the control panel, and
clean or replace if necessary. Check whether the unit
is being affected by an external heat source. If the
service message persists, notify Customer Service.
Service 30 When it has been switched on for
30 seconds,
Moisture control not working. The unit can be used
for cooking with limitations. Please notify Customer
Service.
Service 31 When it has been switched on for
30 seconds,
Core temperature probe is defective. The unit can be
used for cooking without the core temperature probe.
Please notify Customer Service.
Service 32 Gas
units
Displayed continuously. Close the gas valve. Please notify Customer Service.