TECHNICAL CHARACTERISTICS
U Aria
Energy efficiency class - - A+
Heating input reduced - nominal kW 2,9 - 6,3
Heating output reduced - nominal kW 2,7 - 5,7
Red. - Nom. Yield % 93,8 - 91,5
Hourly consumption kg/h 0,59 - 1,29
Loading interval h 13 - 29
Heating volume * m
3
100 - 160
CO at 13% of O
2
% 0,017 - 0,004
mg/m
3
215 - 45
OGC at 13% of O
2
mg/m
3
4 - 4
NO
X
at 13% of O
2
mg/m
3
101 - 116
PM at 13% of O
2
mg/m
3
14 - 14,9
Smoke temperature °C 74 - 121
Smoke ow g/s 3,3 - 5,1
Minimum draft Pa - mbar 10 - 0,1
Electrical connection Hz - V 50 - 230
Electrical power consumption max. W 260
Electrical power consumption reduced - nominal W 30 - 50
Stand-by electrical consumption W 3,8
smoke air inlet Ø mm 35
smoke outlet pipe Ø mm 80
Hopper capacity kg 17
Seasonal energy eciency %
87,8
Type of room temperature control with electronic room tempera-
ture control plus week timer
Other control options with distance control option
The data shown here is provided as a guideline and is not binding, and may change based on what type and quality of wood is
used. Ravelli reserves the right to make any changes in order to improve product performance.
* Heatable volume based on the requested power equal to 35 W/m³ and 55 W/m³
Minimum clearances from