EasyManua.ls Logo

Ravelli Aria - Technical Characteristics

Ravelli Aria
56 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Use and maintenance manual Aria
Pag.19
Rev.0 22/04/2022
EN
TECHNICAL CHARACTERISTICS
U Aria
Energy efficiency class - - A+
Heating input reduced - nominal kW 2,9 - 6,3
Heating output reduced - nominal kW 2,7 - 5,7
Red. - Nom. Yield % 93,8 - 91,5
Hourly consumption kg/h 0,59 - 1,29
Loading interval h 13 - 29
Heating volume * m
3
100 - 160
CO at 13% of O
2
% 0,017 - 0,004
mg/m
3
215 - 45
OGC at 13% of O
2
mg/m
3
4 - 4
NO
X
at 13% of O
2
mg/m
3
101 - 116
PM at 13% of O
2
mg/m
3
14 - 14,9
Smoke temperature °C 74 - 121
Smoke ow g/s 3,3 - 5,1
Minimum draft Pa - mbar 10 - 0,1
Electrical connection Hz - V 50 - 230
Electrical power consumption max. W 260
Electrical power consumption reduced - nominal W 30 - 50
Stand-by electrical consumption W 3,8
smoke air inlet Ø mm 35
smoke outlet pipe Ø mm 80
Hopper capacity kg 17
Seasonal energy e󰀩ciency %
87,8
Type of room temperature control with electronic room tempera-
ture control plus week timer
Other control options with distance control option
The data shown here is provided as a guideline and is not binding, and may change based on what type and quality of wood is
used. Ravelli reserves the right to make any changes in order to improve product performance.
* Heatable volume based on the requested power equal to 35 W/m³ and 55 W/m³
Minimum clearances from
combustible materials
Aria
R Right side 200 mm
L Left side 200 mm
B Rear 100 mm
A Front 800 mm
RL
B
A

Table of Contents