PAGE 17/24 | Calibration manual | 016-8000-015EN | Rev. A
CALIBRATE ISO RAVEN STEERING CONTROLLER | CR7 AUTOSTEERING | RAVEN EUROPE GENERIC
45
The screen as in the right figure appears.
After pressing the button, The Disengage
pressure is being calibrated. Make sure the
machine is on a flat surface and wheels can
move without causing damage.
Press the ‘Start’ button.
46
The disengage sensor is being calibrated.
Follow the instructions on the screen.
The first few secons, do not touch the
steering wheel!
47
After a few seconds, the instructions change
from not touching to turn the steering wheel
at a typical rate.
When this instruction shows, turn the
steering wheel at a normal speed from left to
right and back again. Do not stop steering
until the next step pops up.
48
After the steering, the next screen appears.
Stop steering. The Disenage Pressure is now
set at a calibrated value. When the
disengage status is green, the system is able
to autosteer.