EasyManua.ls Logo

Raven Spra-Coupe SCS 460 - Calculating Rate 1 and Rate 2 Cal

Raven Spra-Coupe SCS 460
47 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
13
5. CALCULATING "RATE 1 AND RATE 2 CAL"
Determine the application rate at which chemical is to be sprayed. Consult with
a dealer to ensure these spray nozzles are capable of applying at this rate. In
determining which spray nozzles to use with the sprayer the following must be
known:
1) Nominal Application Pressure ___ PSI [kpa]
2) Target Application Rate ___ GPA [lit/ha]
3) Target Speed ___ MPH [km/h]
4) Nozzle Spacing ___ inches [cm]
From this information, calculate the volume per minute, per nozzle as follows:
GPM [lit/min] = GPA [lit/ha] x MPH [km/h] x inches [cm]
5,940 [60,000]
EXAMPLE: 1) Application Pressure =
30 PSI
2) Target Application Rate =
20 GPA
3) Target Speed = 5.2 MPH
4) Nozzle Spacing = 20 inches
GPM = 20 GPA x 5.2 MPH x 20 inches = .35
5,940
Using GPM .35 and pressure 30 select tip number XR8004 from the chart below, since it
comes closest to providing the desired output.
VERIFYING FLOW RATE LIMITS:
The flow rate of spraying must be within the range of that specified for the Flow
Meter included.
FLOW METER MODEL FLOW RANGE
RFM 5 0.05-5 GPM [0.2-18.9 lit/min]
RFM 15 0.3-15 GPM [1.1-56.8 lit/min]
RFM 60P 1-60 GPM [3.8-210 lit/min]
RFM 100 3-100 GPM [11.4-380 lit/min]
RFM 200/200 Poly 15-200 GPM [56.8-760 lit/min]
RFM 400 25-400 GPM [94.6-1515 lit/min]

Related product manuals