6
RayClic-PC, RayClic-PS, RayClic-PT Installation Instructions
1"
2
1
Remove exposed braid.
Push end seal completely onto heating cable.
End Seal Installation
3
1
/8"
1"
HWAT
H
W
A
T
IceStop and XL-Trace
HWAT
IceStop and XL-Trace
Note: The end seal is designed to be
installed only once; it cannot be removed from the
heating cable once installed. Do not use until ready
for final installation.
HWAT
H
W
A
T
IceStop and XL-Trace
HWAT
IceStop and XL-Trace
2A
3
Score around and down the outer
jacket 1-inch from the end.
Remove the outer jacket.
Do not cut or damage the inner jacket.
Using wire cutters, cut away aluminum wrap
close to braid and outer jacket.