20 DS400 and DS500 Digital Fishfinders
Checking the Angle and Projection
Do not position the bow of the transducer lower than the stern
because aeration will occur.
Do not position the transducer farther into the water than necessary
to avoid increasing drag, spray, and water noise and reducing boat
speed.
1. Using a straight edge, sight the underside of the transducer relative to the
underside of the hull (see Figure 2-9 ). The stern of the transducer should
be 13mm (1/161/8") below the bow of the transducer or parallel to the
bottom of the hull.
Figure 2-9: Transducer Angle Adjustment
2. Using the vertical adjustment space in the bracket slots, slide the trans-
ducer up or down (see Figure 2-10 ). Be sure the bottom left corner of the
transducer projections 3mm (1/8") below the bottom of the hull.
13˚ transom angle
14 17 angle
20° transom angle transom angle
parallel
slight angle
angle
reversed
angle
too steep
shim with shim with
taper down taper up
slight angle
slight angle
D6767-1