ENGINE-DRIVEN
ALUMINUM WATER PUMP
6RLAG-2LST
Owner's Manual
ENGLISH
redlionproducts.com
EN
Table Of Contents
Safety Instructions ...............................................................................2
Introduction ..........................................................................................4
Application ........................................................................................... 4
Specifications ....................................................................................... 4
Pump Placement .................................................................................5
Operation ..............................................................................................5
Maintenance ......................................................................................... 7
Cleaning ................................................................................................7
Draining the Pump ..............................................................................8
Transporting the Pump ....................................................................... 8
Storage .................................................................................................8
Troubleshooting ...................................................................................9
Replacement Parts .............................................................................10
Limited Warranty .................................................................................11

Questions and Answers

  • A
    Alejandro MckeeAug 14, 2025
    How to fix red lion 6RLAG-2LST that will not prime?
    • M
      Mr. Roger HamiltonAug 14, 2025
      If your Red Lion Water Pump will not prime, it may be due to excessive suction lift. Move the pump closer to the liquid source.
  • J
    Jeremy GarciaAug 17, 2025
    What to do if Red Lion Water Pump loses prime?
    • D
      Daisy KeyAug 17, 2025
      If your Red Lion Water Pump loses prime, it's likely because the water level drops below the end of the suction hose. Make sure the end of the suction hose is submerged.
  • C
    craig31Aug 21, 2025
    Why does priming my red lion 6RLAG-2LST take a long time?
    • K
      Kimberly WilliamsAug 21, 2025
      If priming your Red Lion Water Pump takes a long time, it may be because the suction hose is quite long. Refer to the PUMP PLACEMENT section. Also, check the hose for loose connections, as air pockets or leaks in the suction hose could be the reason.
  • E
    elynnAug 25, 2025
    What to do if my red lion 6RLAG-2LST Water Pump will not start?
    • J
      jtuckerAug 26, 2025
      If your Red Lion Water Pump won't start, there are several potential causes: * There may be no fuel. Add fuel per the engine manufacturer’s instructions. * The spark plug might be faulty. Replace the spark plug. * The fuel valve lever could be in the OFF position. Turn the fuel valve lever to the ON position. * The ignition switch might be in the OFF position. Turn the ignition switch to the ON position. * The choke may be in the wrong position. Slide the choke lever to the START position.
  • A
    Ashley WaltonAug 28, 2025
    Why my red lion 6RLAG-2LST Water Pump will not pump?
    • J
      Johnny JonesAug 29, 2025
      If your Red Lion Water Pump isn't pumping, it could be due to several reasons: * There might be an air leak in the suction hose. Ensure the suction hose is double clamped at joints, clamps are tight, fittings have thread compound and are tight, with no nicks or cuts in the hose. * The suction and/or discharge hoses may be blocked, or the valves are closed, faulty, or blocked. Check to see that the hoses and valves are in good working order. * The end of the suction hose might not be submerged. The end of the suction hose must be submerged. * The total head could be too high for the pump. Reduce the total head or use a higher head pump.
  • J
    Jessica DaySep 5, 2025
    Why does my red lion 6RLAG-2LST start but run roughly?
    • D
      Debra AllisonSep 5, 2025
      If your Red Lion Water Pump starts but runs roughly, consider these potential causes: * The choke may be in the wrong position. Slide the choke lever to the RUN position. * The spark plug wire may be loose. Attach the wire to the spark plug securely. * The spark plug might be faulty. Replace the spark plug. * The fuel could be contaminated with water or debris. Allow the engine to cool, then drain the fuel tank and carburetor, and fill the tank with fresh fuel. * The oil level might be low. Add oil per the engine manufacturer’s instructions.
  • J
    Jennifer KelleySep 9, 2025
    Why does my red lion 6RLAG-2LST Water Pump shut down during operation?
    • D
      daniel51Sep 9, 2025
      If your Red Lion Water Pump shuts down during operation, it could be due to: * No fuel. Add fuel per the engine manufacturer’s instructions. * Low oil level. Add oil per the engine manufacturer’s instructions.
  • M
    Mary HobbsDec 3, 2025
    How to improve performance of my Red Lion Water Pump?

    Summary

    Safety Instructions

    Before Getting Started

    Instructions for initial setup and safety checks before operating the pump.

    Product Specific Precautions

    Introduction

    Application

    Specifications

    Pump Placement

    Operation

    Preparing the Engine

    Steps and precautions for preparing the engine before operation.

    Priming the Pump

    Operating the Pump

    Maintenance

    Cleaning

    Steps for cleaning the pump housing and its components after use.

    Draining the Pump

    Transporting the Pump

    Storage

    Troubleshooting

    Replacement Parts

    Limited Warranty

    Applicable Warranty Period

    Duration of the warranty coverage for the product.

    Instructions Applicable to Limited Warranty

    Steps consumers must follow to submit a warranty claim.

    Limitations Applicable to Limited Warranty

    Conditions and exclusions under which the warranty is not valid.

    red lion 6RLAG-2LST Specifications

    General IconGeneral
    Brandred lion
    Model6RLAG-2LST
    CategoryWater Pump
    LanguageEnglish

    Related product manuals