20
Auto diagnosis
The unit performs an advanced auto diagnosis of the internal circuits.
The following possible errors can by displayed in the front unit PGMMOD00.
CJ.ER - CJC sensor defect or CJC temperature outside range
FL.ER - Flash error
AO.ER - No load on the current output (only for S4...20 mA / S20...4 mA)
NO.CO - Connection error
IN.ER - Error levels on input
TY.ER - Setup in PGMMOD00 does not match this product type or firmware
revision
Selection of units
After choosing the input signal type you can choose which process units should
be displayed in text line 2 (see table). By selection of temperature input the
process value is always displayed in Celsius or Fahrenheit. This is selected in
the menu point after selection of temperature input.