-2-
Released 2015-11-23 Bulletin No. G307K2-F
Drawing No. LP0889
1. POWER REQUIREMENTS:
Must use Class 2 or SELV rated power supply.
Power connection via removable three position terminal block.
Supply Voltage:24 VDC ±20%, Class 2
Maximum Power:250 mA @ 24 VDC
Fuse:Fast-blow 800 mA, 5x20 mm
2. BATTERY: Lithium coin cell. Typical lifetime of 10 years.
3. LCD DISPLAY:
4. TOUCHSCREEN: Four-wire resistive analog
5. MEMORY:
On Board User Memory: 128 Mbyte of non-volatile Flash memory.
Memory Card: SD slot accepts standard capacity cards up to 2 Gbyte.
6. COMMUNICATIONS: Three Serial Ports - One RS-232 port, two RS-
232/422/485: One Ethernet Port
Serial Ports: Format and Baud Rates for each port are individually
software programmable up to 115,200 baud.
Ethernet Port: 10/100 Mbps
7. ENVIRONMENTAL CONDITIONS:
Operating Temperature Range: 0 to 45°C
Operating and Storage Humidity: 10-90% relative humidity (non-
condensing) from -20 to 60°C.
Vibration
: Operational 10 to 25 Hz, in X, Y, Z direction, 30 minutes, 2 g.
8. CERTIFICATIONS AND COMPLIANCES:
SAFETY
UL Listed, File #E302106, UL508
UL Type 4 Indoor Use Only Enclosure rating (Face only), UL50
IP65 Enclosure rating (Face only), IEC 529
ELECTROMAGNETIC COMPATIBILITY
Consult factory for EMC specifications
9. CONNECTIONS: Compression cage-clamp terminal block.
Wire Gage: 12-28 AWG copper wire
Communications: DB9 connectors
10. CONSTRUCTION: Plastic enclosure with Type 4/IP65 front panel
when properly installed.
11. WEIGHT: 30 oz. (850 g)
SIZE 7-INCH
TYPE TFT
COLORS 32K
PIXELS 800 X 480
BRIGHTNESS
375 cd/m
2
BACKLIGHT TYPE LED
BACKLIGHT LIFE 30,000 HR TYP.
MOUNTINGINSTRUCTIONS
The unit can be mounted into enclosures with a depth of 4". It is
recommended that the unit be mounted on the front panel of a steel
enclosure. Allow clearance of 1" around the sides of the unit for the
mounting hardware. Allow 2.5" along the bottom edge if using Red Lion
communication cables.
Place the unit in the panel cutout. Slide clamps into the four holes
provided at the top and bottom of the case. Tighten the clamping screws in
an even pattern until the unit is secured in the panel. Caution: Do not over
tighten the clamps. To seal to Type 4 specifications, all supplied mounting
clamps must be used. (Torque is 2.6 – 3.5 in/lb.) The panel must not flex
more than 0.010".
7.888 (200.35)
5.762
(146.35)
7.476 (189.9)
5.350
(135.9)
1.675 (42.55)
COM CPU PWR
DIMENSIONS In inches (mm)
VESA Mount: VESA 75 (75 mm x 75 mm). Use four screws (M4-0.7 mm) less than 8 mm long.
R.08 (R2)
7.56 (192)
5.43 (138)