5. Click on the Menu Icon, then select "Configure".
6. Adjust the settings as needed and click "Save" see figure 3.3.
7. Press the "Setup" button on the front of the SRPT-02 to apply your
settings. The repeater is now ready for normal operation.
Setup Options:
Enable Station ID:
When enabled, your call sign will be transmitted in Morse code after each SRPT-
02 transmission.
Station ID:
This is your call sign, which will be transmitted in Morse code.
Morse Code WPM:
This is the speed at which Morse code will be transmitted, with options ranging
from 20 to 40 words per minute.
Station ID Delay:
This is the time delay between the voice transmission and the Station ID
transmission, with a default setting of 1000ms (1 second).
Carrier Detect Delay:
This is the delay before confirming a valid carrier detect, used in conjunction with
radio squelch settings to filter out noise or weak signals. The default value is
100ms (0.1 second).
Minimum Message Length:
This setting allows you to re-transmit recorded audio only if the recorded
message meets a minimum length, useful for filtering out unwanted noise or
accidental microphone key presses.
Transmit Delay:
This is the delay time the repeater will wait before transmitting a recorded
message.
Enable LED’s
Unchecking this option disables all status LED’s on the repeater to conserve
power. In this mode the unit will report power on by flashing the power LED two
times and will report power off by flashing once.