15-CLEANING AND MAINTENANCE
PERIODICAL CHECK OF THE DOOR CLOSURE
Make sure the door closure ensures a correct sealing action (with the “paper sheet” test) and that when the door is closed, the closing block
(X in the gure) does not protrude from the sheet metal to which it is secured. For some products it will be necessary to disassemble the
cladding to be able to assess the anomalous protrusion of the block when the door is closed.
END-OF-SEASON SHUTDOWN
At the end of season, before shutting down the boiler, we recommend completely removing pellets from the tank with the use of a
vacuum cleaner with an extension.
When starting up the boiler at the beginning of the season, if the control panel display fails to light up when you press the power switch
(located on the back of the boiler), it could mean that the service fuse needs replacing.
On the rear of the boiler there is a fuse holding compartment which is located underneath the supply socket. Use a screwdriver to open the
fuse-holder compartment and if necessary replace them (3.15 A delayed)