END-OF-SEASON SHUTDOWN
At the end of each season, before switching the product o, it is recommended to remove all the pellets from the hopper with a vacuum
cleaner with a long pipe.
When not in use the appliance must be disconnected from the mains power supply. It is recommended to remove the
power cable for additional safety, especially in the presence of children.
The service fuse may have to be replaced if the control panel display does not switch on when the product is switched on again by pressing
the main switch on its side.
There is a fuse compartment on the side of the product, under the power socket. After having disconnected the plug from the socket, use
a screwdriver to open the cover of the fuse compartment and, if necessary, replace them (3.15 A delayed).
CHECKING THE INTERNAL COMPONENTS
ATTENTION!
The internal electromechanical components must only be checked by qualied personnel whose technical expertise
includes combustion and electricity.
We recommend that an annual maintenance service is carried out with a scheduled service contract. This service is essentially a visual and
functional inspection of the following components: The following is a summary of the checks and/or maintenance that are indispensable
for the correct operation of the product.
PARTS/INTERVAL EVERY DAY EVERY WEEK 15 DAYS 6090 DAYS EVERY SEASON
Cleaning the brazier *
.
Cleaning the ash collection tray* with
the vacuum cleaner
.
Cleaning the ash tray
.
Cleaning the glass
.
Cleaning lower ash tray
.
Cleaning the outlet "T" (outside the
stove)
.
Cleaning the smoke tting
.
Checking the door seal
.
Checking the spark plug
.
* THE FREQUENCY OF CLEANING SHOULD BE INCREASED IF THE PELLETS ARE OF POOR QUALITY