SYSTEM CONFIGURATIONS DEPENDING ON THE MODEL
Upon installation, the product must be set according to the type of system, selecting the appropriate parameter in the “SETTINGS” menu.
The possible congurations are 5, as described below:
Conguration Description
1 Room temperature management via the boiler probe or by enabling the external room thermostat.
2 2.1 Room temperature management via the boiler probe or by enabling the external room thermostat;
instantaneous DHW production with plate heat exchanger
2.2 Room temperature management via the boiler probe or by enabling the external room thermostat;
instantaneous hot domestic water production for boiler or storage tank with thermostat (optional).
3 Room temperature management via boiler probe or enabling the external room thermostat; boiler hot domestic
water production with ntc probe (10 k ß3435).
4 External Puer management controlled by thermostat.
5 External Puer management controlled by ntc probe (10 k ß3435).
CONFIGURATION 1 (FACTORY SETTING FOR HEATING VERSION ONLY)