WHAT TO DO IF THINGS GO WRONG (2)
PROFESSIONAL SERVICE
If the previous “Self Help” checks fail to restore the performance, you should seek professional help.
The person who installed the Powerstream-Eco is probably the best one to investigate and correct it
and is certainly the person to contact if you have had a problem in the guarantee period.
The following additional checklist is provided for the benefit of the qualified service person.
WARNING: SWITCH OFF THE ELECTRICITY AT THE LOCAL ISOLATOR
BEFORE REMOVING THE COVER TO MAKE CHECKS
Little or no water flows
- neon light off.
The water pressure is very low.
Use a pump to boost the supply from
a storage tank.
Cold water only
- neon light off.
The main water is connected to
the OUTLET of the unit.
The water pressure is too low.
The thermal cut-out has
triggered.
The flow switch is not working.
Reconnect the main supply to the
INLET (marked in blue).
Use a pump to boost the supply from
a storage tank.
Reset it by opening the unit and
pushing the button on the cut-out
(diagram 10). Before you do this you
must remove the cause of the
problem.
Contact Redring (see page 2).
Water too cold
- neon light on.
The power select is set too low.
One element is not working.
The Power Supply Voltage has
dropped.
Change the power select to "High”
(diagram 8).
Switch off the electricity supply and
check the resistance of the elements.
You should get the following readings.
Loading (kW) Resistance (Ohms)
9.5 10.6 / 13.8 approx.
10.8 9.6 / 12.1 approx.
The heater should only draw the
following currents:
40 amps for the 9.5kW model
45 amps for the 10.8kW model
Water flow too low or
temperature too high.
The service valve is fitted to the
OUTLET.
There are constrictions in the
plumbing.
Fit the service valve to the INLET of
the unit.
Check the plumbing. Only use PTFE
tape for making pipe joints.
Water goes from hot to
cold.
The service valve is fitted to the
OUTLET.
Fit the service valve to the INLET of
the unit.