OPER.
PAGE 04
3. EMERGENCY STOP
This is an emergency switch and is used to shut down the pump in an emergency
situation. It is of the push-pull type. Depress PUSH knob in to STOP operation.
PULL knob out to REACTIVATE system. NOTE – The HORN/RESET must be
switched one time to restart pump operation.
4. HOUR METER
This instrument is used to record the number of hours the electric system has been
activated. The hourmeter becomes operational when the ignition key is ON.
5. CHECK ENGINE (YELLOW LIGHT)
Light, when lit, is indicating to check the diesel engine for possible problems.
6. STOP ENGINE (RED LIGHT)
Light, when lit, indicates to STOP ENGINE immediately, it requires attention.
7. DIGITAL DISPLAY
The control panel’s digital display indicates the following areas: The engine RPM,
the OIL PRESSURE, the VOLTS,ENGINE TEMP,COOLANT LEVEL and the status
of the SYSTEMS.
8. PUMP POWER SWITCH (GREEN LIGHT)
This is a two (2) position toggle switch and is used to control the pump ON/OFF
feature.
8A FAST CHANGE SWITCH (C-SERIES ONLY closed loop hyd. system)
This is a two (2) position toggle switch and is used to control the FAST CHANGE
feature, that changes the hydraulic pump to run smoother in certain appiications.
8B PUMP DIRECTION SWITCH
This is a three (3) position toggle switch and is used to control the cycle direction of
the concrete pump. CENTER position of toggle is PUMP-OFF. Move toggle to UP
position to activate PUMP-ON AND FORWARD cycling. Move toggle in DOWN
position for REVERSE cycling.
8C VIBRATOR (OPTION THAT GOES ON THE HOPPER GRATE)
This is a three (3) position toggle switch and is used to control the vibrator
8D DIAGNOSTIC INTERFACE (FACTORY AND FACTORY DEALERS ONLY)
This is a RS-232 computer port that is used for factory system settings and system
diagnostic analysis.