EasyManua.ls Logo

REED R5004 - Operating Voltage; Power Supply; Power Consumption

REED R5004
8 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
reedinstruments
www
com
4
Pantone 534 Blue
Pantone 123 Yellow
Pantone 485 Red
Pantone 123 Yellow
Pantone 534 Blue
Black
Rich Black -
20/20/20/100
Blue - 100/80/30/5
Yellow - 0/27/100/0
Red - 10/100/100/5
Yellow - 0/27/100/0
Blue - 100/80/30/5
Only if you REALLY need them:
Pantone 534 Blue - 100/80/30/5
Pantone 485 Red - 10/100/100/5
Pantone 123 Yellow - 0/27/100/
Protection type: IP40
Protection levels: CATIII600V, CATIV300V
Standards: DIN VDE 0411, IEC 61010 DIN,
VDE 0413-7, IEC 61557-7/EN 61557-7
Operating voltage: Multiple connections: 40 to 600V AC
between phases;
Single connection: 120 to 400V AC
between phases
Power supply: 9V alkaline, IEC 6LR61
Power consumption: Max 20 mA
Battery life: Minimum 1 year of average use
Dimensions: 128 x 68 x 30mm
Weight: 185g
Includes: 3 test leads, 3 test probes, 3 alligator clips,
and one 9V battery
Rotary Field Direction
Nominal voltage rotary direction: 1 to 400V AC
Nominal voltage phase indirection: 120 to 400V AC
Frequency range: 2 to 400HZ
Test currents (in per phase): <3.5mA
Non-contact rotary eld indication frequency range:
2 to 400HZ
Motor Connection
Nominal test voltage (U me): 1 to 400V AC
Nominal test currents (In per phase): Less than 3.5mA
Frequency range (fn): 2 to 400HZ