REFU Elektronik GmbH REFUsol 08K ... 23K 11
2.6
Protection during Handling and Assembly
WARNING
Danger of injury during improper handling caused by crushing, shearing,
cutting, striking, and lifting
The weight of the inverter is 38.4 kg!
Follow the general setup and safety regulations for handling and assembly.
Use suitable assembly and transportation equipment.
Avoid trap and crush injuries by taking suitable precautions.
Only use suitable tools. Use special tools where this is prescribed.
Use lifting equipment and tools in a technically correct manner.
2.7
Please Note Before Starting Up
• In the event of installation in France, the device must be furnished with the warning sticker laid
down by UTE C 15-712-1. The warning stickers are included in delivery.
• Problem-free and safe operation of the inverter is conditional upon due and specialised
transportation, storage, assembly and installation as well as careful operation and maintenance.
• Only use accessories and spare parts approved by the manufacturer.
• Adherence must be ensured to the prescriptions and stipulations regarding safety of the country in
which the inverter is to be used.
• The ambient conditions stated in the product documentation must be observed.
• Starting up is prohibited until the entire system meets the national regulations and safety rules
regarding use.
• Operation is only permitted with adherence to the national EMC prescriptions for the present use
case.
• The manufacturer of the equipment or machine is responsible for ensuring compliance with the
thresholds required by the respective national regulations.
• For European countries, the EU Directive 2014/30/EU (EMC Directive) is to be observed when using
the inverter.
• The technical data, connection and installation conditions are to be taken from the product
documentation and must be observed under all circumstances.
• Switching off of the inverter must first be effected on the AC side via the circuit breaker. Then the
inverter is to be switched off on the DC side, should maintenance work need to be carried out on the
DC side.
• It is not necessary to switch off the inverter overnight, as the inverter switches off completely as
soon as no DC voltage is present at the input. If no switch-off is effected, the inverter switches on
automatically in the morning when the PV generator supplies sufficiently high voltage. This means
that the maximum output is generated.