Installation and Operating Manual
REFUsol 08K ... 23K
English
REFU Elektronik GmbH No. 982030, Version 02 2018-06

Table of Contents

Questions and Answers

  • K
    Kayla FletcherSep 4, 2025
    How to fix PM isolation LT error on REFU Inverter?
    • C
      Christopher PenaSep 4, 2025
      If your REFU Inverter shows a PM isolation LT error, it means the power section detects an isolation error on activation. Check system isolation. If you consider the isolation resistance to be in order, contact Service.
  • K
    Katie RussellSep 18, 2025
    What does Keep Alive mean on REFU REFUsol 10K Inverter?
    • S
      Stacy SalazarSep 18, 2025
      If your REFU Inverter displays Keep Alive error, it means internal communication monitoring has determined a fault. Please contact Service.
  • R
    Robert White MDSep 16, 2025
    What to do if REFU REFUsol 10K displays SR parameter error?
    • J
      Jose ThompsonSep 16, 2025
      If your REFU Inverter displays an SR parameter error, it signifies an error in parameter initialization, and the device has been permanently shut down. Please contact Service.
  • A
    aimeesimsSep 14, 2025
    What to do if REFU REFUsol 10K Inverter showing update fault?
    • D
      Denise CallahanSep 14, 2025
      If your REFU Inverter displays an update fault, it means the update has failed. Contact Service.
  • D
    Destiny WolfSep 12, 2025
    What to do if REFU REFUsol 10K shows Supply voltage LT error?
    • R
      Robert JonesSep 13, 2025
      If your REFU Inverter displays a Supply voltage LT error, it means the supply voltage at the power section is too low. Please contact Service.
  • L
    Loretta JonesSep 12, 2025
    What does Activation LT 4 mean on REFU Inverter?
    • J
      Jonathan FarrellSep 12, 2025
      If your REFU Inverter displays Activation LT 4 error, it means balancing has failed. Please contact Service.
  • R
    Ronald JuarezSep 9, 2025
    How to resolve Initialisation C1 error on REFU REFUsol 10K?
    • T
      Todd GreenSep 9, 2025
      If your REFU Inverter displays an Initialisation C1 error, restart the inverter. If this does not rectify the error, contact Service.
  • K
    Kathryn BrownSep 7, 2025
    What to do if REFU REFUsol 10K Inverter shows DC-voltage measurement error?
    • R
      rebeccacunninghamSep 7, 2025
      If your REFU Inverter displays a DC-voltage measurement error (DC link 3), wait for the measurements to become stable again. If this takes more than 2-3 hours, please contact Service.
  • D
    Danielle BlankenshipSep 5, 2025
    What does Communication LT mean on REFU REFUsol 10K?
    • J
      Jacqueline RhodesSep 5, 2025
      If your REFU Inverter shows Communication LT error, it means there is a communication malfunction between the power section and the control and regulation unit. The inverter will acknowledge the error automatically. If the problem occurs repeatedly, contact Service.
  • D
    Donna BakerAug 21, 2025
    What to do if REFU Inverter shows RCD fault?
    • A
      Anthony MccannAug 21, 2025
      If the AFI-Board unit in your REFU Inverter detects a residual current, it will lead to an immediate shutdown. Check the system isolation. If you believe the isolation impedance is fine, contact Service.

Summary

Safety Information

Intended Use

Describes the designated use of the REFUsol inverter.

Qualification of Personnel

Specifies the required qualifications for personnel working with the inverter.

Dangers Arising from Misuse

Lists potential dangers and risks associated with improper use of the inverter.

Protection against Contact with Electrical Parts

Details safety measures to prevent contact with electrical components.

Protection against Contact with Hot Parts

Advises on precautions to avoid burns from hot surfaces.

Protection during Handling and Assembly

Outlines safety measures for handling and assembling the inverter.

Please Note Before Starting Up

Lists essential checks and conditions before initial startup.

Description of Device

DC Connection

Details the DC connection points and procedures for the inverter.

Installation

Assembly Site Requirements

Specifies the environmental and safety requirements for the inverter installation location.

Installation

Provides instructions for mounting and installing the inverter.

Device connectors

Describes the various connectors available on the inverter unit.

Grounding

Explains the importance and procedure for grounding the inverter.

Residual Current Protection

Details requirements for residual current protection devices.

Power Connection

Provides instructions for connecting the inverter to the power supply.

Power Supply Line

Covers specifications and guidelines for the power supply line connection.

DC connection PV generator

Explains how to connect the PV generator to the inverter.

DC-Connection

Provides detailed information on DC connection types and components.

Connect PHOENIX CONTACT connector (SUNCLIX)

Guides on connecting the SUNCLIX connector.

Commissioning

Turning on the Device

Step-by-step guide for powering on the inverter.

Setting the Country Code and the Menu Language

Instructions for initial configuration of country code and language.

Set Country Code;Grid Guideline

How to select the country code and grid guideline parameters.

Device Start

Describes the startup procedure and status indicators after commissioning.

Configuration

Limitation of the Power Output

How to configure a limit for the inverter's power output.

Monitoring with REFUlog

Guide on connecting to and using the REFUlog monitoring portal.

Troubleshooting

Maintenance

Technical data