Installation and Operating Manual
REFUsol 08K ... 23K
English
REFU Elektronik GmbH No. 982030, Version 02 2018-06

Table of Contents

Questions and Answers

  • D
    denise87Sep 2, 2025
    What to do if REFU REFUsol 10K Inverter showing overtemperature LT 1?
    • R
      Reginald GarciaSep 2, 2025
      If your REFU Inverter displays an overtemperature LT 1 error, it indicates a cooler overtemperature (right). Check the temperature of the direct surroundings and reduce it as required.
  • A
    Amber MartinAug 31, 2025
    Why REFU REFUsol 10K Inverter shows external cut-off error?
    • J
      James JohnsonAug 31, 2025
      If your REFU Inverter detects an external cut-off, it means external monitoring has triggered a disconnection. Verify the external cut-off signal. Possible causes include wire breakage or a wrong sensor selection. Refer to the manual for the correct settings.
  • C
    Caleb JohnsonAug 29, 2025
    How to troubleshoot PM isolation RCD SR error on REFU REFUsol 10K?
    • D
      Douglas BennettAug 29, 2025
      If your REFU Inverter shows a PM isolation RCD SR error, it means the measured value of the residual currents are over the limits. Check system isolation. If you consider the system isolation to be in order, contact Service.
  • D
    David CrawfordAug 28, 2025
    What causes grid frequency LT error in REFU REFUsol 10K Inverter?
    • C
      cynthia94Aug 28, 2025
      If your REFU Inverter displays a grid frequency LT error, it means the power section has detected under/overfrequency. Check the frequency of the phases. If you consider the frequencies to be in order, contact the Service.
  • R
    randall01Aug 27, 2025
    Why REFU REFUsol 10K showing overvoltage 2?
    • C
      coopertammyAug 27, 2025
      If your REFU Inverter detects overvoltage 2, the phase voltage has exceeded the limit value of the voltage average monitor for too long. Monitor line voltages and analyze the grid. If the line voltages appear to be in order, contact Service.
  • J
    Julia TerryAug 25, 2025
    What to do if REFU REFUsol 10K showing overfrequency?
    • S
      Stephanie WongAug 25, 2025
      If your REFU Inverter is detecting an overfrequency, it means the grid frequency has exceeded the limit value. Check the frequency of the phases. If you believe the frequencies are normal, contact Service.
  • G
    Gary GonzalezAug 22, 2025
    How to fix grid overvoltage on REFU REFUsol 10K Inverter?
    • D
      Dale ClaytonAug 22, 2025
      If your REFU Inverter displays a grid overvoltage error, it means a phase overvoltage (AC) has been detected. Check the phase voltages using a true RMS measurement device. If the phase voltages appear normal, contact Service.

Summary

Safety Information

Intended Use

Describes the designated use of the REFUsol inverter.

Qualification of Personnel

Specifies the required qualifications for personnel working with the inverter.

Dangers Arising from Misuse

Lists potential dangers and risks associated with improper use of the inverter.

Protection against Contact with Electrical Parts

Details safety measures to prevent contact with electrical components.

Protection against Contact with Hot Parts

Advises on precautions to avoid burns from hot surfaces.

Protection during Handling and Assembly

Outlines safety measures for handling and assembling the inverter.

Please Note Before Starting Up

Lists essential checks and conditions before initial startup.

Description of Device

DC Connection

Details the DC connection points and procedures for the inverter.

Installation

Assembly Site Requirements

Specifies the environmental and safety requirements for the inverter installation location.

Installation

Provides instructions for mounting and installing the inverter.

Device connectors

Describes the various connectors available on the inverter unit.

Grounding

Explains the importance and procedure for grounding the inverter.

Residual Current Protection

Details requirements for residual current protection devices.

Power Connection

Provides instructions for connecting the inverter to the power supply.

Power Supply Line

Covers specifications and guidelines for the power supply line connection.

DC connection PV generator

Explains how to connect the PV generator to the inverter.

DC-Connection

Provides detailed information on DC connection types and components.

Connect PHOENIX CONTACT connector (SUNCLIX)

Guides on connecting the SUNCLIX connector.

Commissioning

Turning on the Device

Step-by-step guide for powering on the inverter.

Setting the Country Code and the Menu Language

Instructions for initial configuration of country code and language.

Set Country Code;Grid Guideline

How to select the country code and grid guideline parameters.

Device Start

Describes the startup procedure and status indicators after commissioning.

Configuration

Limitation of the Power Output

How to configure a limit for the inverter's power output.

Monitoring with REFUlog

Guide on connecting to and using the REFUlog monitoring portal.

Troubleshooting

Maintenance

Technical data