O P T I G O R E G U L A T O R R E A D Y - S T E A D Y - G O
Optigo OP10 Manual
©Copyright AB Regin, Sweden, 2007

Table of Contents

Other manuals for Regin OPTIGO OP10

Question and Answer IconNeed help?

Do you have a question about the Regin OPTIGO OP10 and is the answer not in the manual?

Summary

Introduction to Optigo

Available Control Modes

Lists the five pre-programmed control modes available for the Optigo OP10 controller.

Technical Data

General Specifications

Covers essential technical parameters like supply voltage, consumption, ambient conditions, and dimensions.

Input Specifications

Lists the specifications for the controller's analogue and digital inputs, including sensor types and ranges.

Output Specifications

Details the specifications for the controller's analogue and digital outputs, including voltage and current ratings.

Installation and Wiring

Supply Voltage Details

Details the specific supply voltage requirements (24V AC) and transformer connection considerations.

Detailed Input;Output Connections

Provides detailed descriptions of each input and output terminal function and connection requirements.

Control Modes

Supply Air with Outdoor Compensation

Explains supply air temperature control where the setpoint is adjusted based on outdoor temperature.

Cascade Room;Exhaust Air Control

Details cascade control for room/exhaust air, using PI and P loops for setpoint adjustment.

Universal Input UI1 Functions

Explains the configuration of the universal input for electric heating limit switches or frost protection sensors.

Outdoor Temperature Compensation

Explains how the supply air setpoint is displaced based on outdoor temperature in control mode 2.

Alarm Handling

Alarm Indicator and Output

Describes the alarm indicator on the display and potential activation of DO1 as an alarm output.

Classification of Alarm Types

Details the four distinct alarm types: Frost protection, High temperature limit, Fan indication, and Sensor error.

Clock and Scheduler

Scheduler General Functionality

Explains the general function of the scheduler, its points, and how it operates for different control modes.

Configuration Menus

Control Mode Selection (Menus 1.0-5.0)

Guides on selecting one of the five available control modes using the configuration menus.

Output Type Configuration (Menus X.1)

Explains how to choose between analogue 0-10V output or 3-point digital output for actuators.

Mode-Specific Settings (Menus X.6)

Covers damper minimum position, cascade factor, 0° boost, and D-factor for various control modes.

UI1 Functions and More (Menus X.7)

Details UI1 input configurations, pump exercise, and overheating functions for specific control modes.

Resetting to Factory Defaults

Provides the procedure for resetting the OP10 controller to its original factory default settings.

Summary

Introduction to Optigo

Available Control Modes

Lists the five pre-programmed control modes available for the Optigo OP10 controller.

Technical Data

General Specifications

Covers essential technical parameters like supply voltage, consumption, ambient conditions, and dimensions.

Input Specifications

Lists the specifications for the controller's analogue and digital inputs, including sensor types and ranges.

Output Specifications

Details the specifications for the controller's analogue and digital outputs, including voltage and current ratings.

Installation and Wiring

Supply Voltage Details

Details the specific supply voltage requirements (24V AC) and transformer connection considerations.

Detailed Input;Output Connections

Provides detailed descriptions of each input and output terminal function and connection requirements.

Control Modes

Supply Air with Outdoor Compensation

Explains supply air temperature control where the setpoint is adjusted based on outdoor temperature.

Cascade Room;Exhaust Air Control

Details cascade control for room/exhaust air, using PI and P loops for setpoint adjustment.

Universal Input UI1 Functions

Explains the configuration of the universal input for electric heating limit switches or frost protection sensors.

Outdoor Temperature Compensation

Explains how the supply air setpoint is displaced based on outdoor temperature in control mode 2.

Alarm Handling

Alarm Indicator and Output

Describes the alarm indicator on the display and potential activation of DO1 as an alarm output.

Classification of Alarm Types

Details the four distinct alarm types: Frost protection, High temperature limit, Fan indication, and Sensor error.

Clock and Scheduler

Scheduler General Functionality

Explains the general function of the scheduler, its points, and how it operates for different control modes.

Configuration Menus

Control Mode Selection (Menus 1.0-5.0)

Guides on selecting one of the five available control modes using the configuration menus.

Output Type Configuration (Menus X.1)

Explains how to choose between analogue 0-10V output or 3-point digital output for actuators.

Mode-Specific Settings (Menus X.6)

Covers damper minimum position, cascade factor, 0° boost, and D-factor for various control modes.

UI1 Functions and More (Menus X.7)

Details UI1 input configurations, pump exercise, and overheating functions for specific control modes.

Resetting to Factory Defaults

Provides the procedure for resetting the OP10 controller to its original factory default settings.