    Benjamin MelendezAug 22, 2025
    How to fix a REMKO Chiller that's not cooling well?
    • S
      sandra99Aug 22, 2025
      If your REMKO Chiller isn't cooling well, the heating capacity might have been increased; maintain safety zones. The supply temperature could be too high, so reduce the discharge temperature. Air in the system can also cause this; ventilate manually or integrate ventilators. If the liquefaction temperature is too hot, clean the fins, place the unit in the shade, and maintain operating ranges. Incorrect parameter settings could be the cause, so change the settings. If cooling requirements are too low causing sporadic operation, increase the quantity of water by installing a storage module.
  • D
    daviddavisAug 28, 2025
    What to do if REMKO Chiller is not cooling at all?
    • D
      Douglas MorenoAug 28, 2025
      If your REMKO Chiller is not cooling at all, consider these possibilities: the heating capacity might have been increased, so maintain safety zones. The supply temperature might be too high, requiring a reduction in discharge temperature. Air in the system can prevent cooling, so ventilate manually or integrate ventilators. Also, check for a liquefaction temperature that's too hot; if so, clean the fins, place the unit in the shade, and maintain operating ranges. Review and correct any incorrect parameter settings. If the unit operates sporadically due to low cooling requirements, increasing the quantity of water by installing a storage module might help.
  • H
    Holly OwenSep 3, 2025
    Why is water leaking from my REMKO Chiller unit?
    • F
      Felicia ReedSep 3, 2025
      If water is leaking from your REMKO Chiller unit, it is likely due to leaks in the pipes or defective insulation. Seal and insulate the affected areas to resolve this.
  • S
    Sophia ShahNov 9, 2025
    What to do if my REMKO Chiller unit does not start?
    • M
      Meghan WardNov 10, 2025
      If your REMKO Chiller unit doesn't start, there might be several reasons. First, check for a power failure and ensure the voltage is correct, waiting for the unit to restart. If the power fuse or supply is defective, have it checked by authorized personnel. Also, make sure the waiting period isn't too short and schedule longer waiting periods if needed. The regulation might not be working, so connect current and select the COOL operating mode. Other potential issues include incorrect electrical rotational direction (change it), incorrect discharge temperature or parameter settings (change the setting), compressor overheating (maintain operating ranges, clean fins), or high liquefaction temperature (clean fins, place unit in the shade). If frost protection is activated, increase the dischar...
  • K
    Kendra HintonNov 15, 2025
    Why does my REMKO Chiller keep switching off automatically?
    • M
      Meghan WilliamsNov 15, 2025
      Your REMKO Chiller might be automatically switching off due to various reasons. It could be a power failure; check the voltage and wait for the unit to restart. The power fuse or power supply might be defective, requiring maintenance by authorized personnel. Short waiting periods can also cause this issue; schedule longer periods. Other potential causes include incorrect electrical rotational direction (change it), regulation not working (connect current and select the COOL operating mode), incorrect discharge temperature or parameter setting (change setting), high-low pressure alarm, remote control/connection to C2-DIN defective, compressor overheating (maintain operating ranges, clean fins), high liquefaction temperature (clean fins, place unit in the shade), activated frost protection (...