5.34
ENG_UD59817_1
Batterie : dépannage (FKJK - Renault)
2
BATTERY: troubleshooting (2/2)
Connect positive (+) lead A to (+) termi-
nal 1 of the discharged battery, then to
(+) terminal 2 of the battery supplying
the current.
Connect the negative cable (–) B to the
(–) 3 terminal of the battery supplying
the current and then to the (–) 4 termi-
nal of the discharged battery.
Start the engine as normal. As soon as
it starts, disconnect cables A and B in
reverse order (4-3-2-1).
Starting the vehicle using the
battery from another vehicle
If you have to use the battery from an-
other vehicle to start, obtain suitable
jump leads (with a large cross section)
from an approved dealer or, if you al-
ready have jump leads, ensure that
they are in perfect condition.
The two batteries must have an iden-
tical nominal voltage of 12 volts. The
battery supplying the current should
have a capacity (amp-hours, Ah) which
is at least the same as that of the dis-
charged battery.
Ensure that there is no risk of contact
between the two vehicles (risk of short
circuiting when the positive terminals
are connected) and that the discharged
battery is properly connected. Switch
off your vehicle ignition.
Start the engine of the vehicle supply-
ing the current and run it at an interme-
diate engine speed.
Check that there is no con-
tact between leads A and B
and that the positive lead A
is not touching any metal
parts on the vehicle supplying the
current.
Risk of serious injury and/or
damage to the vehicle.