Reneka International – Instruction of use – Edition 01/2008 – Page 10
ALARMS AND DESCRIPTION
VIVA S 710 / VIVA S 940
Type Signals Description Solution
FILLING ALARM
The display shows "
FILLING
Turn the machine off (5 s)
ALARM
" and all the leds are
then swith it on again
blinking
Filling alarm
Blinking of all the leds
It is possible to use the
OUTPUT METER ALARM
The display shows "
OUTPUT
machine but only by
METER ALARM
" and the led of
manual operation on the
the button blinks brewhed in question
Get information with your
Output meter
alarm
Blinking of the led
after-sales service
The filter reaches a remaining
capacity of 100 l
CHANGE FILTER
A buzzer is set off Get information with your
01 99 99 99 99
The display shows "
CHANGE
after-sales service
FILTER
" and the after-sales
Filter alarm
service telephone number appears
Settinf off of a buzzer during
MAINTENANCE
the coffee cycle every 250 cycles.
01 99 99 99 99
The display shows Get information with your
Buzzer
"
MAINTENANCE
" and the after-
after-sales service
sales service telephone number
Maintenance
alarm
appears
The boiler's temperature drops The boiler reaches the
000°C
(Boiler temp.)
below 108°C temperature automatically
TEMP. TO LOW
The display shows the temperature If not, get information
Buzzer
and "
TEMP. TO LOW
" with your after-sales
A buzzer is set off (5 bips of 1 service
Boiler
temperature
alarm
second)
The water level in the boiler The boiler fills
BOILER EMPTY
drops below the safety line automatically
The heating is cut of
The display shows "
BOILER
If not, get information
Boiler water
level alarm
EMPTY
"
with your after-sales service
A buzzer engages and the display Get information with your
PROBE CUT
shows "
PROBE CUT"
after-sales service
Temperature
probe alarm
Buzzer