EasyManua.ls Logo

Renesas RH850/F1KM-S4 - Page 8

Renesas RH850/F1KM-S4
26 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
F1KM-S4, F1KH-D8 272pin PiggyBack board Y-RH850-F1X-272PIN-PB-T2-V1
R20UT4009ED0100 Rev.1.0 8
2017-07-12
Figure 3 Jumper setting overview
The green jumper JP12 for FLMDO0 always must be closed for a ‘normal’
(user mode and debug) operation of the device.
The red jumpers must be set for a “Voltage 1” (typ. +5.0V) operation of
the related device supply.
The blue jumper must be set for a “Voltage 2” (typ. +3.3V) operation of
the related device supply.
Note:
The RH850/F1KH-D8 device requires a supply voltage of 3.3V on its
REG1VCC pin.
The RH850/F1KM-S4 device requires the same supply voltage to be set
to REG0VCC and REG1VCC.
See the section ‘Electrical Characteristics’ in the device User’s Manual for further
details.
For jumper settings related to the device operation mode, refer to the
chapter 6.2.

Related product manuals