Problem Possible cause Corrective action
No air and no abra-
sive
Nozzle blocked.
Nozzle blocked at grip and/or blasting
hose blocked.
Kink(s) in the foot switch connector hose.
Switch set to intermediate position.
Pressure set too low.
Open the blasting nozzle unit and clean the nozzle
(Fig. 23, 24, 25).
Unscrew the nozzle from the handle and blow it out
with compressed air. Without reconnecting the noz-
zle, activate the foot switch to blow compressed air
through the hose.
Inspect and correct the connecting hoses.
Turn the switch until you feel it click into place.
Open the pressure regulator further (recommended
pressure: 4 - 5 bar).
Air only and no or
very little abrasive
Dirty or moist abrasive.
• Insufcientabrasiveintheunit.
Intake hose blocked.
Problems with the additional tank.
Replace the abrasive.
Add abrasive.
Check that the intake hose is not kinked / pinched /
blocked. The intake hose must be securely attached
to the unit base (Fig. 7).
Refer to “Additional tank - Mounting instructions”,
No. 21-9774.
Reduced blasting
force
Function selector switch not properly set.
Nozzle worn.
Abrasive used up.
Abrasive feed hose is blocked /
damaged / kinked.
• Insufcientabrasiveinthereservoir.
Make sure the selector switch clicks into place.
Replace the nozzle.
Replace the abrasive.
Drain the abrasive out and inspect / replace the feed
hose.
Add abrasive.
Excessive abrasive
consumption
Extraction power set too high. Reduce the extraction power.
Blasting chamber
lls with dust.
• Insufcientextractionpower.
Extractor dust bag full.
The suction performance of a weak extraction unit
can be increased by closing the boreholes on the
back side of the unit (Fig. 14, Pos. b) with the sup-
plied magnetic foil.
Clean the extractor / replace the dust bag.
Abrasive spurts in
pulses.
Nozzle connectors not vertical.
Abrasive used up or too dirty.
Kink in the suction hose.
Make sure the nozzle is vertical.
Replace the abrasive.
Inspect the feed hose.
Unit continuously
blasting and stops
when foot switch is
activated.
Foot switch connected incorrectly. Inspect and correct the foot switch connection.
Foot switch fails to
switch on.
No pressure at the compressed air con-
nection.
Kink(s) in the pneumatic hoses.
Inspect the compressed air lines and compressor.
Realign the hoses.
Air leaking from the
foot switch.
Pneumatic hoses connected incorrectly. Replace the connectors.