5. TROUBLESHOOTING
5.1 INCIDENTS, CAUSES AND REMEDIES
INCIDENTS CAUSES RIMEDIES
Regeneration occurs at the wrong time Clock poorly adjusted Programming the clock
Programmer stops in the regeneration
cycle
Motor burned Replace
Power failure Check the power socket
Incorrect voltage or frequency Check voltage or frequency corrected
Excessive pressure Install pressure regulator
The softener regenerates or
discharges water continuously
Power failure Check voltage
Motor blocked or burned Replace engine
The programmer does not regenerate
automatically or when the start button is
pressed
Power supply disconnected Connect
Defective motor Replace engine
Defective card Replace card
The programmer does not automatically
regenerate but only by means of the start
button
Unscheduled daily regenerations Programming regeneration
Lack of softened water between two
regenerations
Incorrect regeneration
Repeat the regeneration making sure that
the right amount of salt is used
Polluted resins Wash or replace resins
Incorrect programming of the quantity of salt Checking and reprogramming
Poorly adjusted by-pass By-pass to adjust
Lack of brine suction
Insucient supply pressure Ensure at least 1.4 bar
Obstructed exhaust pipe Ensure free discharge
Blocked injector Clean injector
Faulty injector Replace
The brine vat gets too full Programming excessive salt quantity
Reprogram according to the instructions in
the table provided for this purpose
Irregular salt consumption compared to
what was expected
Adjustment error Re-adjust
Intermittent brine suction or irregular
Insucient supply pressure Ensure at least 1.4 bar
Faulty injector Replace injector
After regeneration, the water is not
softened.
The softener hasn’t regenerated Restart regeneration
Lack of salt in the vat Topping up salt in the vat
Exhausted resins Replace resins
Excessive or insucient backwashing rate
The regulator is the wrong type Replace correctly
The regulator is blocked Disassemble and clean
Hard water leakage during operation
Poor regeneration Restart regeneration
O - ring rod seal damaged Replace
Poorly adjusted by-pass Regulate by-pass