RC3000 Antenna Controller Chapter 3 Detailed Operation
117
3.3.1.3.11 SHAKE
AZ 1: -40.0 2: 50.0 3: 0.0 CONF-SHAKE
EL 1: 30.0 2: 40.0 3: -67.5 CYCLE: 100
PL 1: -10.0 2: 10.0 3: 0.0 DELAY: 15
MOVE 1 AZIM <-180.0/180.0>
AZ #: MOVE # AZIM <-180.0/180.0>
The AZ field allows the user to specify the azimuth target for moves 1, 2 or 3.
EL #: MOVE # ELEV <-90.0/90.0>
The EL field allows the user to specify the elevation target for moves 1, 2 or 3.
PL #: MOVE # POL <-180.0/180.0>
The PL field allows the user to specify the polarization target for moves 1, 2 or 3.
CYCLE: NUMBER OF SHAKE CYCLES <1-9999>
The CYCLE field allows the user to specify the total number of movement cycles the SHAKE function will
perform.
DELAY: DELAY <0-999 SECONDS>
The DELAY field allows the user to specify the amount of time (in seconds) that the SHAKE function will
wait between “moves”. Specifying a value of 0 will cause no delay between “moves”.