EasyManua.ls Logo

ResMed S9 VPAP Series User Manual

ResMed S9 VPAP Series
40 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
VPAP
Auto
VPAP
ST
VPAP
S
POSITIVE AIRWAY PRESSURE DEVICE
H5i
HEATED HUMIDIFIER
Clinical Guide
English
Global leaders in sleep and respiratory medicine www.resmed.com
Manufacturer: ResMed Ltd 1 Elizabeth Macarthur Drive Bella Vista NSW 2153 Australia. Distributed by: ResMed Corp
9001 Spectrum Center Boulevard San Diego CA 92123 USA.
ResMed (UK) Ltd 96 Milton Park Abingdon Oxfordshire
OX144RY UK. See www.resmed.com for other ResMed locations worldwide.
S9 VPAP Auto: Protected by patents: AU 691200, AU 697652, AU 699726, AU 702820, AU 709279, AU 713679, AU 724589,
AU730844, AU 731800, AU 736723, AU 750095, AU 750761, AU 756622, AU 764761, AU 779327, AU 2002306200, AU 2005200987,
AU 2007252223, CA 2235939, CA 2263126, CN 200780001837.6, EP 0651971, EP 0661071, EP 0858352, EP 0920845, EP 0927538,
EP 0929336, EP 0934723, EP 1028769, EP 1126893, EP 1502618, EP 2032857, JP 3580776, JP 3635097, JP 3638613, JP 3778797,
JP4083154, JP 4647786, NZ 504595, NZ 570415, NZ 577485, US 5704345, US 6138675, US 6152129, US 6213119, US 6240921,
US6279569, US 6363933, US 6367474, US 6425395, US 6502572, US 6591834, US 6659101, US 6675797, US 6745768, US 6817361,
US 6945248, US 6988498, US 7040317, US 7100608, US 7537010, US 7661428, US 7866944. Other patents pending. Protected
by design registrations: AU 329025, AU 330142, AU 331272, AU 332891, AU 333858, CN 200830346524.1, CN 200830346526.0,
CN200830346525.6, CN 201030215797.X, EU 1067417, JP 1377401, JP 1377402, JP 1377403, JP 1415251, JP 1415252, NZ 411762,
NZ 413090, NZ 413091, US D629891, US D629892, US D635232, US D635244, US D635245, US D635654, US D638536, US D638537,
US D638933. Other design registrations pending.
S9 VPAP ST / S9 VPAP S: Protected by patents: AU 697652, AU 699726, AU 713679, AU 731800, AU 756622, AU 2002306200,
AU 2005200987, AU 2007252223, CA 2235939, CA 2263126, EP 0661071, EP 0858352, EP 0929336, EP 2032857, JP 3635097,
JP3638613, JP 4083154, NZ 577485, US 6152129, US 6213119, US 6240921, US 6279569, US 6659101, US 6945248, US 7661428,
US 7866944. Other patents pending. Protected by design registrations: AU 329025, AU 330142, AU 331272, AU 332891, AU 333858,
CN 200830346524.1, CN 200830346526.0, CN 200830346525.6, CN 201030215797.X, EU 1067417, JP 1377401, JP 1377402,
JP1377403, JP 1415251, JP 1415252, NZ 411762, NZ 413090, NZ 413091, US D629891, US D629892, US D635232, US D635244,
USD635245, US D635654, US D638536, US D638537, US D638933. Other design registrations pending.
H5i: Protected by patents: AU 2002233025, CN ZL02804936.5, HK 1065483, JP 4420605, NZ 527088, US 693533, US 7614398.
Other patents pending. Protected by design registrations: AU 331676, AU 331677, CN 200930203243.5, EU 1720582, JP 1402844,
JP1402845, NZ 413752, NZ 413753, US D626642, US D627044. Other design registrations pending.
S9, H5i, ClimateLine, SlimLine, SmartStart, TiControl, VPAP Auto and VPAP are trademarks of ResMed Ltd and S9, ClimateLine,
SlimLine, SmartStart and VPAP are registered in U.S. Patent and Trademark Office.
© 2011 ResMed Ltd.
368353/3 2011-09
S9 VPAP Series
H5i
CLINICAL
AMER ENG

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the ResMed S9 VPAP Series and is the answer not in the manual?

ResMed S9 VPAP Series Specifications

General IconGeneral
Therapy ModesCPAP, S, T, S/T
Data StorageSD card
Power Supply100-240V AC, 50/60Hz
HumidifierOptional H5i heated humidifier
Operating AltitudeUp to 8, 500 feet (2, 600 meters)

Summary

VPAP Device Introduction

VPAP Indications and Contraindications

Details on when to use VPAP devices and conditions where they are contraindicated.

VPAP Adverse Effects

Potential side effects patients may experience during VPAP therapy.

H5i Humidifier Introduction

H5i Indications and Contraindications

Details on when to use the H5i humidifier and conditions where it is contraindicated.

VPAP at a Glance

Traveling with the VPAP

Advice for patients travelling with the VPAP system, covering tubing and power requirements.

H5i at a Glance

Traveling with the H5i

Instructions for moving or travelling with the H5i, focusing on emptying the water tub.

Operating Information

Bilevel Pressures and Modes

Explains IPAP, EPAP, pressure support and available therapy modes (CPAP, S, ST, T, VAuto).

VAuto Mode and EPR Technology

Details VAuto features and Expiratory Pressure Relief (EPR) settings for comfort.

Breath Control and Leak Management

Covers triggering, cycling, leak compensation (Vsync), and rise time adjustment for breath synchronization.

Advanced Operating Features

Inspiratory Time Control (TiControl)

Explains TiControl parameters (Ti Max, Ti Min) for synchronizing breath delivery and patient effort.

Pressure Range Settings

How to set Min EPAP, Max IPAP, and pressure support in VAuto mode for therapy adjustment.

VPAP Features and Capabilities

Climate Control System

How Climate Control manages humidity and temperature for patient comfort and rainout prevention.

Sleep Apnea Detection and Quality Monitoring

Covers CSA detection, Sleep Quality indicator, and ramp function for therapy.

System Setup and Connection

Connecting VPAP and H5i

Step-by-step guide for physically connecting the VPAP and H5i devices.

Mask and Tubing Configuration

Guidance on selecting appropriate masks and compatible tubing for the VPAP.

Filling the Humidifier Water Tub

Instructions for filling the H5i humidifier water tub with distilled or deionized water.

User Interface and Navigation

VPAP Controls and Interface

Overview of the Start/Stop button, Push Dial, LCD screen, and menu navigation.

Menu Navigation and Home Screen

Steps for navigating menus and understanding the Home screen display.

Adjusting Settings via Home Menu

How to adjust Ramp, Humidity Level, Climate Control, and use Mask-fit from the Home menu.

Viewing and Understanding Therapy Data

Interpreting Treatment Screens

Explains different treatment screens showing humidity, oximetry, and breath parameters.

Clinical Treatment Parameters

Details parameters displayed during therapy, their units, and availability across modes.

Device Configuration and Settings

Patient and Clinical Setup Menus

Options for patients and clinicians to adjust therapy settings, comfort, and accessories.

Clinical Setup Menu Parameters

Detailed breakdown of adjustable parameters within the Clinical Setup menu.

Setup Options and Reminders

Covers options like Climate Control, Sleep Quality, SmartStart, Leak Alert, and reminder settings.

Configuration Settings

Device settings for language, factory defaults, data erasure, and units.

Information Access and Reporting

Managing Reminders and Info Menus

How to set up reminders and access Standard Info menu data (sleep quality, reports, service).

Advanced and Clinical Info Details

Explains Advanced and Clinical Info menus for detailed settings and reports, plus parameter descriptions.

Sleep Report and Service Data

Explains parameters for sleep reports and service data (run hours, software versions).

Managing Climate Control

Climate Control Modes: Auto vs. Manual

Compares Climate Control Auto and Manual modes for humidity and temperature management.

Therapy Delivery and Oxygen Use

Starting and Stopping Therapy

Steps for connecting power, fitting mask, starting, and stopping therapy.

Supplemental Oxygen Compatibility

Compatibility and considerations for using supplemental oxygen with VPAP devices.

SD Card Data Management

SD Card Operations and Analysis

Instructions for SD card operations and analyzing captured therapy data.

Data Storage and Transmission

Information on data storage amounts, sampling rates, and data transmission adapters.

Device Cleaning and Maintenance

Daily, Weekly, and Monthly Cleaning

Procedures for routine cleaning of the VPAP and H5i.

Air Filter Replacement and Checklist

Guidance on replacing the air filter and a general maintenance checklist.

Technical Specifications

General and VPAP Device Specifications

Covers power, environmental, EMC, aircraft use, and VPAP device technical details.

H5i, Tubing, and Humidifier Performance

Technical details for H5i, air tubing, and humidifier performance data.

Flow Path and Display Accuracy

Diagram of pneumatic flow path, maximum flow rates, and displayed value accuracy.

Safety Warnings and Precautions

General and Device Warnings

Important general safety guidelines and specific warnings for device usage and operation.

Device Cautions and Specific Warnings

Precautions for device placement, cleaning, and specific warnings for humidifier and tubing.