Solar / Grundeinstellung
Bezeichnung Werkseinstellung
Schema 001/011 002/012 003/013 004/014
System 1 3.2 3.2 2.1
Kollektor 1
Kollmin Ja Ja Ja Ja
Kollmin 10 °C 10 °C 10 °C 10 °C
Kollnot 130 °C 130 °C 130 °C 130 °C
Kollektor 2
Kollmin Ja Ja Ja Ja
Kollmin 10 °C 10 °C 10 °C 10 °C
Kollnot 130 °C 130 °C 130 °C 130 °C
Speicher 1
ΔTein 6 K 6 K 6 K 6 K
ΔTaus 2 K 2 K 2 K 2 K
ΔTsoll 10 K 10 K 10 K 10 K
Spsoll 65 °C 65 °C 65 °C 65 °C
Spmax 95 °C 95 °C 95 °C 95 °C
Vorrang 1 2 1 1
HysSp 2 K 2 K 2 K 2 K
Anstieg 2 K 2 K 2 K 2 K
tMin 30s 30s 30s 30s
Min. Drehzahl 30% 30% 30% 30%
Deaktiviert Nein Nein Nein Nein
Speicher 2
ΔTein 6 K 6 K 6 K 6 K
ΔTaus 4 K 2 K 2 K 4 K
ΔTsoll 10 K 10 K 10 K 10 K
Spsoll 45 °C 60 °C 26 °C 45 °C
Spmax 60 °C 60 °C 30 °C 60 °C
Vorrang 2 1 2 2
HysSp 2 K 2 K 2 K 2 K
Anstieg 2 K 2 K 2 K 2 K
tMin 30s 30s 30s 30s
Min. Drehzahl 30% 30% 30% 30%
Deaktiviert Nein Nein Nein Nein
Ladelogik
Pendelp. 2 min 2 min 4 min 2 min
Umwälz. 15 min 60 min 30 min 15 min
Pausendrehzahl Nein Nein Nein Nein
Pumpenverzögerung 30s 30s 30s 30s