Functions and Options Page: 25 Menu: Solar Configuration settings for solar thermal system operation and optimization.
Bypass Setting up the bypass function to prevent energy extraction from the store during loading.
Collector Cooling Function Function to cool the collector by transferring heat to a free store when maximum temperature is reached.
Recooling Function to keep system temperatures low by temporarily overriding store maximum temperature.
Frost Protection Activating frost protection for the loading circuit to prevent freezing of the medium.
Target Temperature Setting the target temperature for pump speed control based on collector temperature.
Parallel Relay Activating a parallel relay when the solar circuit pump is switched on.
CS-Bypass Operating the collector circuit when irradiation exceeds a set bypass value.
St2on... St4on Removing specific stores from solar control, meaning they are no longer considered for loading.
Store Loading Parameters controlling store loading based on temperature differences and maximum limitations.
Hysteresis Defining the temperature difference for switching store loading on/off after maximum limitation.
Arrangement Page: 31 Store Loading Configuration for store loading, monitoring switch-on/off levels and reference sensors.
Function blocks Assigning functions like thermostat, timer, and differential control to relays.
Heating Circuits Control settings for up to 4 independent weather-compensated heating circuits.
Heating curve Adjusting the heating curve to match building heating load and influence flow set temperature.
Mixer Controlling the mixing valve position based on flow temperature and set flow temperature difference.
Sommer Setting an outdoor temperature threshold to switch off the heating circuit during summer.
Timer Configuring time frames for day or night correction of heating circuit flow temperature.
Flow Sensor Allocating a sensor for measuring flow rate in the heating circuit.
Afterheating Configuring afterheating based on store temperature or direct heat source reference.
Sensor 1 store Selecting the 1st reference sensor for heating circuit afterheating.
Sensor 2 store Selecting the 2nd reference sensor for store-dependent afterheating.
Afterheating demand Selecting the relay for demanding afterheating and setting minimum/overrun times.
Chimney sweeper Activating the chimney sweeper function to open the heating circuit and switch on the pump.
DHW heating option Enabling DHW heating by demanding afterheating based on sensor temperature.
DHW priority option Prioritizing DHW heating over other functions, with timer options for specific time frames.
Expert Menu Page: 41 Chimney sweeper Activates a specific relay state for functions like flue gas measurement.
Solar shutdown Deactivates solar control and monitoring for errors in the solar thermal system.
Sensor offset Adjusting the CS-type and applying offsets to sensor readings for accurate measurements.
Minimum speed Setting the minimum pump speed for speed-controlled pumps, or disabling control.
Maximum speed Adjusting the maximum pump speed for corresponding outputs.
Language Selecting the display language for the controller interface.