EasyManua.ls Logo

Resol DeltaSol E User Manual

Resol DeltaSol E
48 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
www.resol.com
DeltaSol
®
E
Manual
RESOL DeltaSol
®
E (Version 2)
Mounting
Connection
Operation
Troubleshooting
Thank you for buying this RESOL product.
Please read this manual carefully to get the best performance from this unit.
en
The Internet portal for easy and secure access
to your system data – www.vbus.net
*11206125*
11206125

Other manuals for Resol DeltaSol E

Questions and Answers:

Resol DeltaSol E Specifications

General IconGeneral
BrandResol
ModelDeltaSol E
CategoryController
LanguageEnglish

Summary

Manual Overview and Safety

Safety Advice

General safety instructions to avoid danger and damage to people and property.

Target Group

Information exclusively addressed to authorised skilled personnel for installation and operation.

Information about the product

Details on proper usage, CE Declaration of conformity, and electromagnetic field considerations.

Technical Data

Installation

Montage

Step-by-step guide for mounting the controller unit, including cover removal and wall fastening.

Electrical Connection

Overview of Electrical Connections

Diagram and explanation of all electrical connection points for sensors, mains, and outputs.

Actuators (Pumps, Valves etc.)

Details on connecting pumps, valves, and auxiliary relays to the controller's output terminals.

Data Communication/Bus

Information on connecting the controller to external modules via the RESOL VBus® data bus.

Sensors

Guide to connecting various temperature and irradiation sensors to the controller's input terminals.

Mains Supply

Instructions for connecting the controller to the power supply via an external power switch.

PWM Outputs

Details on using PWM outputs for controlling the speed of high-efficiency pumps.

Operation and Function

Buttons for Adjustment

Explanation of how to navigate menus and adjust settings using the controller's buttons.

Control Lamp

Description of the control lamp's colours and flashing patterns for signalling system status.

Menu Structure

Overview of the controller's menu hierarchy and navigation flow.

User Codes

Information on different user access levels (Expert, User, Customer) and their respective codes.

Menu Overview

Detailed graphical overview of all available menu options and their interconnections.

Commissioning

Basic Systems and Hydraulic Variants

Selection guide for basic system configurations and hydraulic variants based on heat sources and sinks.

Function Blocks

Explanation of function blocks for controlling various system components and operations.

Adjusting the Controller Step-by-Step

A sequential guide to configuring controller settings for optimal system operation.

Overview of Relay and Sensor Allocation

Tables showing how relays and sensors are assigned to different system configurations.

Functions and Options

Menu: Solar

Configuration settings for solar thermal system operation and optimization.

Bypass

Setting up the bypass function to prevent energy extraction from the store during loading.

External Heat Exchanger

Configuration for linking loading circuits separated by an external heat exchanger.

Tube Collector Function

Function to compensate for non-ideal sensor positions in tube collectors.

Cooling Function (1-Store Systems)

Enabling cooling for 1-store systems when store temperature exceeds maximum limitation.

Collector Cooling Function

Function to cool the collector by transferring heat to a free store when maximum temperature is reached.

Recooling

Function to keep system temperatures low by temporarily overriding store maximum temperature.

Frost Protection

Activating frost protection for the loading circuit to prevent freezing of the medium.

Target Temperature

Setting the target temperature for pump speed control based on collector temperature.

Parallel Relay

Activating a parallel relay when the solar circuit pump is switched on.

CS-Bypass

Operating the collector circuit when irradiation exceeds a set bypass value.

Afterheating Suppression

Suppressing afterheating when a solar store is being loaded for energy supply.

Collector Emergency Shutdown

Shutting down the collector if its temperature exceeds a critical threshold.

Collector Minimum Limitation

Setting a minimum temperature that must be exceeded for the solar pump to switch on.

St2on... St4on

Removing specific stores from solar control, meaning they are no longer considered for loading.

Store Loading

Parameters controlling store loading based on temperature differences and maximum limitations.

Store Maximum Limitation

Setting the maximum temperature for a store, which stops loading when reached.

Hysteresis

Defining the temperature difference for switching store loading on/off after maximum limitation.

Arrangement

HSE (Protection Against Legionella)

Function to periodically heat DHW stores to prevent Legionella growth.

Store Loading

Configuration for store loading, monitoring switch-on/off levels and reference sensors.

Function blocks

Assigning functions like thermostat, timer, and differential control to relays.

Heating Circuits

Control settings for up to 4 independent weather-compensated heating circuits.

Heating curve

Adjusting the heating curve to match building heating load and influence flow set temperature.

Mixer

Controlling the mixing valve position based on flow temperature and set flow temperature difference.

Sommer

Setting an outdoor temperature threshold to switch off the heating circuit during summer.

Timer

Configuring time frames for day or night correction of heating circuit flow temperature.

Flow Sensor

Allocating a sensor for measuring flow rate in the heating circuit.

Outdoor temperature sensor

Allocating a sensor for measuring the outdoor temperature for heating circuit control.

Afterheating

Configuring afterheating based on store temperature or direct heat source reference.

Sensor 1 store

Selecting the 1st reference sensor for heating circuit afterheating.

Sensor 2 store

Selecting the 2nd reference sensor for store-dependent afterheating.

Afterheating demand

Selecting the relay for demanding afterheating and setting minimum/overrun times.

Manual correction (remote control)

Manually adjusting the heating curve or switching the heating circuit off via remote control.

Sensor remote control

Allocating a sensor for the remote control unit's temperature readings.

Chimney sweeper

Activating the chimney sweeper function to open the heating circuit and switch on the pump.

External heating module

Activating and configuring additional external heating circuit modules (HKM).

Screed drying option

Time and temperature controlled screed drying function for heating circuits.

DHW heating option

Enabling DHW heating by demanding afterheating based on sensor temperature.

DHW priority option

Prioritizing DHW heating over other functions, with timer options for specific time frames.

Loading pump option

Activating the loading pump in parallel to DHW afterheating demand.

Legionella protection option

Systematically activating afterheating to prevent Legionella spread in DHW stores.

Heat Quantity Measurement

Expert Menu

System warning “△T too high"

Displays a message if solar loading differential exceeds a set limit for a period.

System warning “Non-ret. valve“

Displays a message for high collector temperature or store loading at night.

Message relay (error message)

Activates a message relay when the controller detects faults like sensor defects.

Chimney sweeper

Activates a specific relay state for functions like flue gas measurement.

Solar shutdown

Deactivates solar control and monitoring for errors in the solar thermal system.

Sensor offset

Adjusting the CS-type and applying offsets to sensor readings for accurate measurements.

Minimum speed

Setting the minimum pump speed for speed-controlled pumps, or disabling control.

Maximum speed

Adjusting the maximum pump speed for corresponding outputs.

Pump speed control

Selecting the pump control type: On/Off, Puls, PSol, PHEA, or 0-10V.

Relay allocation

Allocating relays to specific PWM outputs for pump control.

Language

Selecting the display language for the controller interface.

VBus

Manual Mode

Troubleshooting

Accessories

Sensors and Measuring Instruments

Overview of available temperature sensors, flowmeters, and overvoltage protection devices.

VBus® Accessories

Details on smart displays, alarm modules, and other VBus® compatible accessories.

Interface Adapters

Information on VBus®/USB and VBus®/LAN interface adapters for PC connection.

Related product manuals